{"product_id":"alco-controls-fse-02s-804706-sensitive-control-module","title":"ALCO Controls FSE-02S \/ 804706 Fan Speed Control Module, 15.5 bar","description":"\u003cp\u003eThe \u003cstrong\u003eALCO Controls FSE-02S\u003c\/strong\u003e (Part No. \u003cstrong\u003e804706\u003c\/strong\u003e) is an electronic fan speed control module that generates a 0-10 V signal from condensing pressure, for R22, R407C, R404A and R507 systems.\u003c\/p\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; border: 1px solid #e0e0e0; font-size: 13px; margin-top: 20px; font-family: sans-serif;\"\u003e\n\u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n\u003ctd style=\"padding: 8px 10px; background-color: #f9f9f9; font-weight: bold; width: 35%; color: #333; line-height: 1.5; vertical-align: top;\"\u003eModel\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 10px; color: #555; line-height: 1.5; vertical-align: top;\"\u003eFSE-02S\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n\u003ctd style=\"padding: 8px 10px; background-color: #f9f9f9; font-weight: bold; width: 35%; color: #333; line-height: 1.5; vertical-align: top;\"\u003ePart No.\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 10px; color: #555; line-height: 1.5; vertical-align: top;\"\u003e804706\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n\u003ctd style=\"padding: 8px 10px; background-color: #f9f9f9; font-weight: bold; width: 35%; color: #333; line-height: 1.5; vertical-align: top;\"\u003eRefrigerants\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 10px; color: #555; line-height: 1.5; vertical-align: top;\"\u003eR22, R407C, R404A, R507\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n\u003ctd style=\"padding: 8px 10px; background-color: #f9f9f9; font-weight: bold; width: 35%; color: #333; line-height: 1.5; vertical-align: top;\"\u003eAdjustment Range\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 10px; color: #555; line-height: 1.5; vertical-align: top;\"\u003e10–21 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n\u003ctd style=\"padding: 8px 10px; background-color: #f9f9f9; font-weight: bold; width: 35%; color: #333; line-height: 1.5; vertical-align: top;\"\u003eFactory Setting\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 10px; color: #555; line-height: 1.5; vertical-align: top;\"\u003e15.5 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n\u003ctd style=\"padding: 8px 10px; background-color: #f9f9f9; font-weight: bold; width: 35%; color: #333; line-height: 1.5; vertical-align: top;\"\u003eMax. Operating Pressure (PS)\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 10px; color: #555; line-height: 1.5; vertical-align: top;\"\u003e32 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n\u003ctd style=\"padding: 8px 10px; background-color: #f9f9f9; font-weight: bold; width: 35%; color: #333; line-height: 1.5; vertical-align: top;\"\u003eTest Pressure (PT)\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 10px; color: #555; line-height: 1.5; vertical-align: top;\"\u003e36 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n\u003ctd style=\"padding: 8px 10px; background-color: #f9f9f9; font-weight: bold; width: 35%; color: #333; line-height: 1.5; vertical-align: top;\"\u003eOutput Signal\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 10px; color: #555; line-height: 1.5; vertical-align: top;\"\u003e0–10 VDC, max 1 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n\u003ctd style=\"padding: 8px 10px; background-color: #f9f9f9; font-weight: bold; width: 35%; color: #333; line-height: 1.5; vertical-align: top;\"\u003eSupply Voltage\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 10px; color: #555; line-height: 1.5; vertical-align: top;\"\u003e10 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n\u003ctd style=\"padding: 8px 10px; background-color: #f9f9f9; font-weight: bold; width: 35%; color: #333; line-height: 1.5; vertical-align: top;\"\u003ePressure Connection\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 10px; color: #555; line-height: 1.5; vertical-align: top;\"\u003e7\/16\"-20 UNF female, brass\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n\u003ctd style=\"padding: 8px 10px; background-color: #f9f9f9; font-weight: bold; width: 35%; color: #333; line-height: 1.5; vertical-align: top;\"\u003eProtection\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 10px; color: #555; line-height: 1.5; vertical-align: top;\"\u003eIP65 with PS3-Nxx cable assembly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n\u003ctd style=\"padding: 8px 10px; background-color: #f9f9f9; font-weight: bold; width: 35%; color: #333; line-height: 1.5; vertical-align: top;\"\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 10px; color: #555; line-height: 1.5; vertical-align: top;\"\u003e-20 to +65 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n\u003ctd style=\"padding: 8px 10px; background-color: #f9f9f9; font-weight: bold; width: 35%; color: #333; line-height: 1.5; vertical-align: top;\"\u003eWeight\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 10px; color: #555; line-height: 1.5; vertical-align: top;\"\u003e125 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003cp\u003eThe module suits condenser fan speed control in commercial refrigeration and air-conditioning systems.\u003c\/p\u003e\n\u003cp\u003eApexon Supply provides B2B sourcing and replacement support for \u003cstrong\u003eALCO Controls FSE-02S\u003c\/strong\u003e, including procurement review and technical alignment for industrial buyers.\u003c\/p\u003e\n\u003cp\u003eRequest a B2B quote for sourcing support. Send the MPN, quantity, and application requirements for RFQ support. Most qualified RFQs receive a response or quote within 12 hours.\u003c\/p\u003e","brand":"ALCO","offers":[{"title":"Default Title","offer_id":54559971803415,"sku":null,"price":500.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0837\/9210\/1655\/files\/alco-controls-fse-02s-804706-sensitive-control-module.webp?v=1795435683","url":"https:\/\/www.apexonsupply.com\/products\/alco-controls-fse-02s-804706-sensitive-control-module","provider":"Apexon Solutions LLC","version":"1.0","type":"link"}