{"product_id":"autronica-bh-300-optical-smoke-detector-interactive-with-selfverify-thermistor-10-27-vdc-point-detector","title":"AUTRONICA BH-300 \/ 116-BHH-300 Optical Smoke Detector, 10–27 VDC, IP44D","description":"\u003cp\u003eThe \u003cstrong\u003eAUTRONICA BH-300\u003c\/strong\u003e is an interactive optical smoke detector that operates on the photoelectric light-scatter principle for detection of combustion gases mainly consisting of visible particles. The BH-300 version includes SelfVerify functionality and a built-in thermistor for temperature measurement at the detector point. The manufacturer lists \u003cstrong\u003ePart number 116-BHH-300\u003c\/strong\u003e for the detector head.\u003c\/p\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; border: 1px solid #e0e0e0; font-size: 13px; margin-top: 20px; font-family: sans-serif;\"\u003e\n\u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n\u003ctd style=\"padding: 8px 10px; background-color: #f9f9f9; font-weight: bold; width: 35%; color: #333; line-height: 1.5; vertical-align: top;\"\u003eVersion\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 10px; color: #555; line-height: 1.5; vertical-align: top;\"\u003eBH-300\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n\u003ctd style=\"padding: 8px 10px; background-color: #f9f9f9; font-weight: bold; width: 35%; color: #333; line-height: 1.5; vertical-align: top;\"\u003ePart number\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 10px; color: #555; line-height: 1.5; vertical-align: top;\"\u003e116-BHH-300\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n\u003ctd style=\"padding: 8px 10px; background-color: #f9f9f9; font-weight: bold; width: 35%; color: #333; line-height: 1.5; vertical-align: top;\"\u003ePrinciple\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 10px; color: #555; line-height: 1.5; vertical-align: top;\"\u003ePhotoelectric, light scatter principle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n\u003ctd style=\"padding: 8px 10px; background-color: #f9f9f9; font-weight: bold; width: 35%; color: #333; line-height: 1.5; vertical-align: top;\"\u003eVoltage\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 10px; color: #555; line-height: 1.5; vertical-align: top;\"\u003e10–27 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n\u003ctd style=\"padding: 8px 10px; background-color: #f9f9f9; font-weight: bold; width: 35%; color: #333; line-height: 1.5; vertical-align: top;\"\u003eStandby Current Consumption\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 10px; color: #555; line-height: 1.5; vertical-align: top;\"\u003e\u0026lt; 0.3 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n\u003ctd style=\"padding: 8px 10px; background-color: #f9f9f9; font-weight: bold; width: 35%; color: #333; line-height: 1.5; vertical-align: top;\"\u003eExternal Alarm Indicator Current\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 10px; color: #555; line-height: 1.5; vertical-align: top;\"\u003e6 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n\u003ctd style=\"padding: 8px 10px; background-color: #f9f9f9; font-weight: bold; width: 35%; color: #333; line-height: 1.5; vertical-align: top;\"\u003eDegree of Protection\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 10px; color: #555; line-height: 1.5; vertical-align: top;\"\u003eIP44D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n\u003ctd style=\"padding: 8px 10px; background-color: #f9f9f9; font-weight: bold; width: 35%; color: #333; line-height: 1.5; vertical-align: top;\"\u003eWorking Temperature\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 10px; color: #555; line-height: 1.5; vertical-align: top;\"\u003e-20 to +70°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n\u003ctd style=\"padding: 8px 10px; background-color: #f9f9f9; font-weight: bold; width: 35%; color: #333; line-height: 1.5; vertical-align: top;\"\u003eHumidity\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 10px; color: #555; line-height: 1.5; vertical-align: top;\"\u003eMax. 95% RH, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n\u003ctd style=\"padding: 8px 10px; background-color: #f9f9f9; font-weight: bold; width: 35%; color: #333; line-height: 1.5; vertical-align: top;\"\u003eWeight\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 10px; color: #555; line-height: 1.5; vertical-align: top;\"\u003e150 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n\u003ctd style=\"padding: 8px 10px; background-color: #f9f9f9; font-weight: bold; width: 35%; color: #333; line-height: 1.5; vertical-align: top;\"\u003eMaterials\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 10px; color: #555; line-height: 1.5; vertical-align: top;\"\u003ePC\/ABS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n\u003ctd style=\"padding: 8px 10px; background-color: #f9f9f9; font-weight: bold; width: 35%; color: #333; line-height: 1.5; vertical-align: top;\"\u003eStandards\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 10px; color: #555; line-height: 1.5; vertical-align: top;\"\u003eEN 54-7 \/ EN 54-17\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n\u003ctd style=\"padding: 8px 10px; background-color: #f9f9f9; font-weight: bold; width: 35%; color: #333; line-height: 1.5; vertical-align: top;\"\u003eCPD Certificate\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 10px; color: #555; line-height: 1.5; vertical-align: top;\"\u003e1134-CPD-016\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003cp\u003eThe BH-300 is designed for use with AUTRONICA interactive fire detection systems. The manufacturer identifies industrial, maritime and offshore installations as demanding applications for its DYFI+ intelligence and SelfVerify functions. SelfVerify performs a calibrated detector test once every 24 hours.\u003c\/p\u003e\n\u003cp\u003eApexon Supply provides B2B sourcing, replacement sourcing and technical alignment support for AUTRONICA fire detection components. Buyers should verify the detector version, voltage range, protection degree and system requirements against the original installation before replacement.\u003c\/p\u003e\n\u003cp\u003eSend \u003cstrong\u003eAUTRONICA BH-300\u003c\/strong\u003e or \u003cstrong\u003ePart number 116-BHH-300\u003c\/strong\u003e, required quantity and application requirements for RFQ support. Most qualified RFQs receive a response or quote within 12 hours.\u003c\/p\u003e","brand":"Autronica","offers":[{"title":"Default Title","offer_id":51729541726487,"sku":null,"price":400.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0837\/9210\/1655\/files\/autronica-smoke-detectors-autronica-bh-300-optical-smoke-detector-interactive-with-selfverify-thermistor-10-27-vdc-point-detector-pack-of-1-1212524324.png?v=1766323561","url":"https:\/\/www.apexonsupply.com\/products\/autronica-bh-300-optical-smoke-detector-interactive-with-selfverify-thermistor-10-27-vdc-point-detector","provider":"Apexon Solutions LLC","version":"1.0","type":"link"}