{"product_id":"beckhoff-ek1100-ethercat-coupler-ek1100-24v-dc-supply-2x-rj45-100base-tx-44-100-68-mm","title":"Beckhoff EK1100 EtherCAT Coupler EK1100, 24V DC Supply, 2x RJ45 100BASE-TX, 44×100×68 mm","description":"\u003cdiv\u003e\n  \u003ch2\u003eOverview\u003c\/h2\u003e\n  \u003cp\u003eThe Beckhoff EK1100 EtherCAT Coupler links the EtherCAT protocol at fieldbus level (100BASE‑TX) to EtherCAT Terminals (ELxxxx). It converts Ethernet telegrams to E‑bus signals and automatically detects connected EtherCAT Terminals in the process image. The coupler provides 24 V DC system and field supply and can deliver up to 5 V \/ 2 A to the E‑bus. It features two RJ45 ports for line or optional segment extension. \u003c\/p\u003e\n\n  \u003ch3\u003eKey Features\u003c\/h3\u003e\n  \u003cul\u003e\n    \u003cli\u003eCouples EtherCAT Terminals (ELxxxx) to 100BASE‑TX EtherCAT networks\u003c\/li\u003e\n    \u003cli\u003e2 x RJ45 sockets; station distances up to 100 m (100BASE‑TX)\u003c\/li\u003e\n    \u003cli\u003eSupports up to 65,534 EtherCAT Terminals in the overall system\u003c\/li\u003e\n    \u003cli\u003eE‑bus current supply up to 2000 mA; power contacts up to 24 V DC \/ 10 A\u003c\/li\u003e\n    \u003cli\u003eElectrical isolation 500 V (power contact\/supply\/Ethernet)\u003c\/li\u003e\n    \u003cli\u003eCompact IP20 housing for 35 mm DIN rail mounting\u003c\/li\u003e\n    \u003cli\u003eApprovals: CE, CCC, UL, ATEX, IECEx, DNV, cFMus\u003c\/li\u003e\n  \u003c\/ul\u003e\n\n  \u003ch3\u003eApplications\u003c\/h3\u003e\n  \u003cul\u003e\n    \u003cli\u003eIntegration of EtherCAT Terminals into EtherCAT networks (line or star topologies via EtherCAT junction\/extension)\u003c\/li\u003e\n    \u003cli\u003eInstallation anywhere in the Ethernet signal transfer section (100BASE‑TX) except directly at a switch\u003c\/li\u003e\n  \u003c\/ul\u003e\n\n  \u003ch3\u003eSpecifications\u003c\/h3\u003e\n  \u003ctable style=\"width:100%; border-collapse: collapse; border: 1px solid #e0e0e0; font-size: 14px; margin-top: 10px;\"\u003e\n    \u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n      \u003ctd style=\"padding: 6px 10px; background-color: #f9f9f9; font-weight: bold; width: 35%; color: #333;\"\u003eBrand\u003c\/td\u003e\n      \u003ctd style=\"padding: 6px 10px; color: #555;\"\u003eBeckhoff\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n      \u003ctd style=\"padding: 6px 10px; background-color: #f9f9f9; font-weight: bold; width: 35%; color: #333;\"\u003eSeries\u003c\/td\u003e\n      \u003ctd style=\"padding: 6px 10px; color: #555;\"\u003eEtherCAT Coupler\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n      \u003ctd style=\"padding: 6px 10px; background-color: #f9f9f9; font-weight: bold; width: 35%; color: #333;\"\u003eSpecific MPN\u003c\/td\u003e\n      \u003ctd style=\"padding: 6px 10px; color: #555;\"\u003eEK1100\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n      \u003ctd style=\"padding: 6px 10px; background-color: #f9f9f9; font-weight: bold; width: 35%; color: #333;\"\u003eTask\u003c\/td\u003e\n      \u003ctd style=\"padding: 6px 10px; color: #555;\"\u003eCoupling EtherCAT Terminals (ELxxxx) to 100BASE‑TX EtherCAT networks\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n      \u003ctd style=\"padding: 6px 10px; background-color: #f9f9f9; font-weight: bold; width: 35%; color: #333;\"\u003eProtocol\u003c\/td\u003e\n      \u003ctd style=\"padding: 6px 10px; color: #555;\"\u003eEtherCAT\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n      \u003ctd style=\"padding: 6px 10px; background-color: #f9f9f9; font-weight: bold; width: 35%; color: #333;\"\u003eBus Interface\u003c\/td\u003e\n      \u003ctd style=\"padding: 6px 10px; color: #555;\"\u003e2 × RJ45 (100BASE‑TX)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n      \u003ctd style=\"padding: 6px 10px; background-color: #f9f9f9; font-weight: bold; width: 35%; color: #333;\"\u003eData Transfer Rate\u003c\/td\u003e\n      \u003ctd style=\"padding: 6px 10px; color: #555;\"\u003e100 Mbit\/s; delay approx. 1 μs\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n      \u003ctd style=\"padding: 6px 10px; background-color: #f9f9f9; font-weight: bold; width: 35%; color: #333;\"\u003eDistance Between Stations\u003c\/td\u003e\n      \u003ctd style=\"padding: 6px 10px; color: #555;\"\u003eUp to 100 m (100BASE‑TX)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n      \u003ctd style=\"padding: 6px 10px; background-color: #f9f9f9; font-weight: bold; width: 35%; color: #333;\"\u003eMax. EtherCAT Terminals\u003c\/td\u003e\n      \u003ctd style=\"padding: 6px 10px; color: #555;\"\u003eUp to 65,534\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n      \u003ctd style=\"padding: 6px 10px; background-color: #f9f9f9; font-weight: bold; width: 35%; color: #333;\"\u003ePower Supply\u003c\/td\u003e\n      \u003ctd style=\"padding: 6px 10px; color: #555;\"\u003e24 V DC (-15% \/ +20%)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n      \u003ctd style=\"padding: 6px 10px; background-color: #f9f9f9; font-weight: bold; width: 35%; color: #333;\"\u003eCurrent Consumption (US)\u003c\/td\u003e\n      \u003ctd style=\"padding: 6px 10px; color: #555;\"\u003e70 mA + (∑ E‑bus current \/ 4)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n      \u003ctd style=\"padding: 6px 10px; background-color: #f9f9f9; font-weight: bold; width: 35%; color: #333;\"\u003eE‑bus Current Supply\u003c\/td\u003e\n      \u003ctd style=\"padding: 6px 10px; color: #555;\"\u003e2000 mA (5 V)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n      \u003ctd style=\"padding: 6px 10px; background-color: #f9f9f9; font-weight: bold; width: 35%; color: #333;\"\u003ePower Contacts\u003c\/td\u003e\n      \u003ctd style=\"padding: 6px 10px; color: #555;\"\u003eMax. 24 V DC \/ max. 10 A\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n      \u003ctd style=\"padding: 6px 10px; background-color: #f9f9f9; font-weight: bold; width: 35%; color: #333;\"\u003eElectrical Isolation\u003c\/td\u003e\n      \u003ctd style=\"padding: 6px 10px; color: #555;\"\u003e500 V (power contact \/ supply voltage \/ Ethernet)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n      \u003ctd style=\"padding: 6px 10px; background-color: #f9f9f9; font-weight: bold; width: 35%; color: #333;\"\u003eOperating Temperature\u003c\/td\u003e\n      \u003ctd style=\"padding: 6px 10px; color: #555;\"\u003e-25…+60 °C\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n      \u003ctd style=\"padding: 6px 10px; background-color: #f9f9f9; font-weight: bold; width: 35%; color: #333;\"\u003eProtection \/ Mounting\u003c\/td\u003e\n      \u003ctd style=\"padding: 6px 10px; color: #555;\"\u003eIP20; 35 mm DIN rail (EN 60715); compact terminal housing with LEDs\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n      \u003ctd style=\"padding: 6px 10px; background-color: #f9f9f9; font-weight: bold; width: 35%; color: #333;\"\u003eApprovals \/ Markings\u003c\/td\u003e\n      \u003ctd style=\"padding: 6px 10px; color: #555;\"\u003eCE, CCC, UL, ATEX, IECEx, DNV, cFMus; Ex: ATEX II 3 G Ex ec IIC T4 Gc; IECEx Ex ec IIC T4 Gc\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n      \u003ctd style=\"padding: 6px 10px; background-color: #f9f9f9; font-weight: bold; width: 35%; color: #333;\"\u003eDimensions (W × H × D)\u003c\/td\u003e\n      \u003ctd style=\"padding: 6px 10px; color: #555;\"\u003e44 mm × 100 mm × 68 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n","brand":"Beckhoff","offers":[{"title":"Default Title","offer_id":51785046262039,"sku":null,"price":150.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0837\/9210\/1655\/files\/beckhoff-ethernet-module-beckhoff-ek1100-ethercat-coupler-ek1100-24v-dc-supply-2x-rj45-100base-tx-44x100x68-mm-1215478816.png?v=1767837430","url":"https:\/\/www.apexonsupply.com\/products\/beckhoff-ek1100-ethercat-coupler-ek1100-24v-dc-supply-2x-rj45-100base-tx-44-100-68-mm","provider":"Apexon Solutions LLC","version":"1.0","type":"link"}