{"product_id":"beckhoff-ek1101-ethercat-coupler-ethercat-coupler-with-id-switch-2x-rj45-100base-tx-24v-dc-supply-44-100-68-mm","title":"Beckhoff EK1101 EtherCAT Coupler EtherCAT Coupler with ID Switch, 2x RJ45 100BASE-TX, 24V DC Supply, 44×100×68 mm","description":"\u003cdiv\u003e\n  \u003ch2\u003eOverview\u003c\/h2\u003e\n  \u003cp\u003eThe Beckhoff EK1101 EtherCAT Coupler links 100BASE‑TX EtherCAT networks to EtherCAT Terminals (ELxxxx). It converts Ethernet telegrams to E‑bus signals, auto-detects attached terminals, and includes three hexadecimal ID switches for assigning a unique group ID, enabling flexible, variable topologies. System and field supplies (24 V DC) are provided at the coupler; the E‑bus can supply up to 5 V \/ 2 A to terminals.\u003c\/p\u003e\n\n  \u003ch3\u003eKey Features\u003c\/h3\u003e\n  \u003cul\u003e\n    \u003cli\u003eEtherCAT coupler with identity verification via three hex ID switches (up to 4096 configurable IDs)\u003c\/li\u003e\n    \u003cli\u003e2 × RJ45 ports for 100BASE‑TX; up to 100 m between stations\u003c\/li\u003e\n    \u003cli\u003eSupports up to 65,534 EtherCAT Terminals in the overall system\u003c\/li\u003e\n    \u003cli\u003eE‑bus current supply up to 2000 mA; power contacts up to 24 V DC \/ 10 A\u003c\/li\u003e\n    \u003cli\u003eElectrical isolation 500 V between power contacts, supply voltage, and Ethernet\u003c\/li\u003e\n    \u003cli\u003eCompact IP20 housing; DIN‑rail (EN 60715) mounting; status LEDs\u003c\/li\u003e\n    \u003cli\u003eApprovals: CE, CCC, UL, ATEX, IECEx, DNV, cFMus\u003c\/li\u003e\n  \u003c\/ul\u003e\n\n  \u003ch3\u003eApplications\u003c\/h3\u003e\n  \u003cul\u003e\n    \u003cli\u003eCoupling ELxxxx EtherCAT Terminals to EtherCAT networks with flexible placement using ID switches\u003c\/li\u003e\n    \u003cli\u003eLine or star topologies using EtherCAT junctions\/extensions\u003c\/li\u003e\n    \u003cli\u003eIndustrial control panels requiring compact, DIN-rail mounted couplers\u003c\/li\u003e\n  \u003c\/ul\u003e\n\n  \u003ch3\u003eSpecifications\u003c\/h3\u003e\n  \u003ctable style=\"width:100%; border-collapse: collapse; border: 1px solid #e0e0e0; font-size: 14px; margin-top: 10px;\"\u003e\n    \u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n      \u003ctd style=\"padding: 6px 10px; background-color: #f9f9f9; font-weight: bold; width: 35%; color: #333;\"\u003eBrand\u003c\/td\u003e\n      \u003ctd style=\"padding: 6px 10px; color: #555;\"\u003eBeckhoff\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n      \u003ctd style=\"padding: 6px 10px; background-color: #f9f9f9; font-weight: bold; width: 35%; color: #333;\"\u003eSeries\u003c\/td\u003e\n      \u003ctd style=\"padding: 6px 10px; color: #555;\"\u003eEtherCAT Coupler\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n      \u003ctd style=\"padding: 6px 10px; background-color: #f9f9f9; font-weight: bold; width: 35%; color: #333;\"\u003eSpecific MPN\u003c\/td\u003e\n      \u003ctd style=\"padding: 6px 10px; color: #555;\"\u003eEK1101\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n      \u003ctd style=\"padding: 6px 10px; background-color: #f9f9f9; font-weight: bold; width: 35%; color: #333;\"\u003eFunction\u003c\/td\u003e\n      \u003ctd style=\"padding: 6px 10px; color: #555;\"\u003eCoupling ELxxxx EtherCAT Terminals to 100BASE‑TX EtherCAT networks; identity verification with ID switches\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n      \u003ctd style=\"padding: 6px 10px; background-color: #f9f9f9; font-weight: bold; width: 35%; color: #333;\"\u003eBus Interface\u003c\/td\u003e\n      \u003ctd style=\"padding: 6px 10px; color: #555;\"\u003e2 × RJ45 (100BASE‑TX)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n      \u003ctd style=\"padding: 6px 10px; background-color: #f9f9f9; font-weight: bold; width: 35%; color: #333;\"\u003eData Rate \/ Delay\u003c\/td\u003e\n      \u003ctd style=\"padding: 6px 10px; color: #555;\"\u003e100 Mbit\/s; approx. 1 μs delay\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n      \u003ctd style=\"padding: 6px 10px; background-color: #f9f9f9; font-weight: bold; width: 35%; color: #333;\"\u003eDistance Between Stations\u003c\/td\u003e\n      \u003ctd style=\"padding: 6px 10px; color: #555;\"\u003eMax. 100 m (Cat.5 shielded or better)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n      \u003ctd style=\"padding: 6px 10px; background-color: #f9f9f9; font-weight: bold; width: 35%; color: #333;\"\u003eMax. EtherCAT Terminals\u003c\/td\u003e\n      \u003ctd style=\"padding: 6px 10px; color: #555;\"\u003eUp to 65,534; addressable I\/O up to 4.2 GB\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n      \u003ctd style=\"padding: 6px 10px; background-color: #f9f9f9; font-weight: bold; width: 35%; color: #333;\"\u003eConfigurable IDs\u003c\/td\u003e\n      \u003ctd style=\"padding: 6px 10px; color: #555;\"\u003e4096 (three hexadecimal ID switches)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n      \u003ctd style=\"padding: 6px 10px; background-color: #f9f9f9; font-weight: bold; width: 35%; color: #333;\"\u003ePower Supply\u003c\/td\u003e\n      \u003ctd style=\"padding: 6px 10px; color: #555;\"\u003e24 V DC (-15% \/ +20%)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n      \u003ctd style=\"padding: 6px 10px; background-color: #f9f9f9; font-weight: bold; width: 35%; color: #333;\"\u003eCurrent Consumption (US)\u003c\/td\u003e\n      \u003ctd style=\"padding: 6px 10px; color: #555;\"\u003e70 mA + (∑ E‑bus current \/ 4)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n      \u003ctd style=\"padding: 6px 10px; background-color: #f9f9f9; font-weight: bold; width: 35%; color: #333;\"\u003eE‑bus Current Supply\u003c\/td\u003e\n      \u003ctd style=\"padding: 6px 10px; color: #555;\"\u003e2000 mA (5 V)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n      \u003ctd style=\"padding: 6px 10px; background-color: #f9f9f9; font-weight: bold; width: 35%; color: #333;\"\u003ePower Contacts\u003c\/td\u003e\n      \u003ctd style=\"padding: 6px 10px; color: #555;\"\u003eMax. 24 V DC \/ max. 10 A\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n      \u003ctd style=\"padding: 6px 10px; background-color: #f9f9f9; font-weight: bold; width: 35%; color: #333;\"\u003eElectrical Isolation\u003c\/td\u003e\n      \u003ctd style=\"padding: 6px 10px; color: #555;\"\u003e500 V (power contact \/ supply voltage \/ Ethernet)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n      \u003ctd style=\"padding: 6px 10px; background-color: #f9f9f9; font-weight: bold; width: 35%; color: #333;\"\u003eOperating Temperature\u003c\/td\u003e\n      \u003ctd style=\"padding: 6px 10px; color: #555;\"\u003e-25…+60 °C (storage -40…+85 °C)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n      \u003ctd style=\"padding: 6px 10px; background-color: #f9f9f9; font-weight: bold; width: 35%; color: #333;\"\u003eProtection \/ Mounting\u003c\/td\u003e\n      \u003ctd style=\"padding: 6px 10px; color: #555;\"\u003eIP20; 35 mm DIN rail (EN 60715); compact terminal housing with LEDs\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n      \u003ctd style=\"padding: 6px 10px; background-color: #f9f9f9; font-weight: bold; width: 35%; color: #333;\"\u003eDimensions (W × H × D)\u003c\/td\u003e\n      \u003ctd style=\"padding: 6px 10px; color: #555;\"\u003e44 mm × 100 mm × 68 mm; weight ≈ 105 g\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n","brand":"Beckhoff","offers":[{"title":"Default Title","offer_id":51785142042903,"sku":null,"price":300.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0837\/9210\/1655\/files\/beckhoff-ethernet-module-beckhoff-ek1101-ethercat-coupler-ethercat-coupler-with-id-switch-2x-rj45-100base-tx-24v-dc-supply-44x100x68-mm-1215478812.png?v=1767837397","url":"https:\/\/www.apexonsupply.com\/products\/beckhoff-ek1101-ethercat-coupler-ethercat-coupler-with-id-switch-2x-rj45-100base-tx-24v-dc-supply-44-100-68-mm","provider":"Apexon Solutions LLC","version":"1.0","type":"link"}