{"product_id":"beckhoff-el1008-ethercat-terminal-8-channel-digital-input-24v-dc-3-ms-input-filter-12-100-68-mm","title":"Beckhoff EL1008 EtherCAT Terminal, 8‑Channel Digital Input 24V DC, 3 ms Input Filter, 12×100×68 mm","description":"\u003cdiv\u003e\n  \u003ch2\u003eOverview\u003c\/h2\u003e\n  \u003cp\u003eThe Beckhoff EL1008 is an EtherCAT Terminal that acquires eight 24 V DC binary input signals and transmits them galvanically isolated to the controller. Each channel has an LED status indicator. A built-in 3 ms input filter suppresses contact bounce from mechanical switches.\u003c\/p\u003e\n\n  \u003ch3\u003eKey Features\u003c\/h3\u003e\n  \u003cul\u003e\n    \u003cli\u003e8-channel 24 V DC digital input (EN 61131-2, type 1\/3)\u003c\/li\u003e\n    \u003cli\u003e3 ms input filter for bounce suppression\u003c\/li\u003e\n    \u003cli\u003eElectrical isolation between E-bus and field potential\u003c\/li\u003e\n    \u003cli\u003eCompact 12 mm-wide IP20 terminal for 35 mm DIN rail\u003c\/li\u003e\n    \u003cli\u003eLED indication per channel\u003c\/li\u003e\n    \u003cli\u003eApprovals: CE, CCC, UL, ATEX, IECEx, DNV, cFMus\u003c\/li\u003e\n  \u003c\/ul\u003e\n\n  \u003ch3\u003eApplications\u003c\/h3\u003e\n  \u003cul\u003e\n    \u003cli\u003eGeneral-purpose 24 V DC input acquisition in EtherCAT systems\u003c\/li\u003e\n    \u003cli\u003eMechanical switch and sensor inputs requiring debounce filtering\u003c\/li\u003e\n  \u003c\/ul\u003e\n\n  \u003ch3\u003eSpecifications\u003c\/h3\u003e\n  \u003ctable style=\"width:100%; border-collapse: collapse; border: 1px solid #e0e0e0; font-size: 14px; margin-top: 10px;\"\u003e\n    \u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n      \u003ctd style=\"padding: 6px 10px; background-color: #f9f9f9; font-weight: bold; width: 35%; color: #333;\"\u003eSpecific MPN\u003c\/td\u003e\n      \u003ctd style=\"padding: 6px 10px; color: #555;\"\u003eEL1008\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n      \u003ctd style=\"padding: 6px 10px; background-color: #f9f9f9; font-weight: bold; width: 35%; color: #333;\"\u003eFunction\u003c\/td\u003e\n      \u003ctd style=\"padding: 6px 10px; color: #555;\"\u003e8-channel digital input terminal for EtherCAT\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n      \u003ctd style=\"padding: 6px 10px; background-color: #f9f9f9; font-weight: bold; width: 35%; color: #333;\"\u003eConnection Technology\u003c\/td\u003e\n      \u003ctd style=\"padding: 6px 10px; color: #555;\"\u003e1‑wire\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n      \u003ctd style=\"padding: 6px 10px; background-color: #f9f9f9; font-weight: bold; width: 35%; color: #333;\"\u003eSpecification\u003c\/td\u003e\n      \u003ctd style=\"padding: 6px 10px; color: #555;\"\u003eEN 61131‑2, type 1\/3\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n      \u003ctd style=\"padding: 6px 10px; background-color: #f9f9f9; font-weight: bold; width: 35%; color: #333;\"\u003eNominal Voltage\u003c\/td\u003e\n      \u003ctd style=\"padding: 6px 10px; color: #555;\"\u003e24 V DC (−15%\/+20%)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n      \u003ctd style=\"padding: 6px 10px; background-color: #f9f9f9; font-weight: bold; width: 35%; color: #333;\"\u003eSignal Voltage “0” \/ “1”\u003c\/td\u003e\n      \u003ctd style=\"padding: 6px 10px; color: #555;\"\u003e“0”: −3…+5 V; “1”: 11…30 V (type 3)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n      \u003ctd style=\"padding: 6px 10px; background-color: #f9f9f9; font-weight: bold; width: 35%; color: #333;\"\u003eInput Current\u003c\/td\u003e\n      \u003ctd style=\"padding: 6px 10px; color: #555;\"\u003etyp. 3 mA (type 3)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n      \u003ctd style=\"padding: 6px 10px; background-color: #f9f9f9; font-weight: bold; width: 35%; color: #333;\"\u003eInput Filter\u003c\/td\u003e\n      \u003ctd style=\"padding: 6px 10px; color: #555;\"\u003etyp. 3 ms\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n      \u003ctd style=\"padding: 6px 10px; background-color: #f9f9f9; font-weight: bold; width: 35%; color: #333;\"\u003eCurrent Consumption (E‑bus)\u003c\/td\u003e\n      \u003ctd style=\"padding: 6px 10px; color: #555;\"\u003etyp. 90 mA\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n      \u003ctd style=\"padding: 6px 10px; background-color: #f9f9f9; font-weight: bold; width: 35%; color: #333;\"\u003eCurrent Consumption (Power Contacts)\u003c\/td\u003e\n      \u003ctd style=\"padding: 6px 10px; color: #555;\"\u003etyp. 2 mA + load; power contacts up to 10 A\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n      \u003ctd style=\"padding: 6px 10px; background-color: #f9f9f9; font-weight: bold; width: 35%; color: #333;\"\u003eElectrical Isolation\u003c\/td\u003e\n      \u003ctd style=\"padding: 6px 10px; color: #555;\"\u003e500 V (E‑bus \/ field potential)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n      \u003ctd style=\"padding: 6px 10px; background-color: #f9f9f9; font-weight: bold; width: 35%; color: #333;\"\u003eDimensions (W × H × D)\u003c\/td\u003e\n      \u003ctd style=\"padding: 6px 10px; color: #555;\"\u003e12 mm × 100 mm × 68 mm; IP20\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n      \u003ctd style=\"padding: 6px 10px; background-color: #f9f9f9; font-weight: bold; width: 35%; color: #333;\"\u003eApprovals\u003c\/td\u003e\n      \u003ctd style=\"padding: 6px 10px; color: #555;\"\u003eCE, CCC, UL, ATEX, IECEx, DNV, cFMus\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n","brand":"Beckhoff","offers":[{"title":"Default Title","offer_id":51785164128535,"sku":null,"price":160.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0837\/9210\/1655\/files\/beckhoff-ethernet-module-beckhoff-el1008-ethercat-terminal-8-channel-digital-input-24v-dc-3-ms-input-filter-12x100x68-mm-1215518546.png?v=1767844749","url":"https:\/\/www.apexonsupply.com\/products\/beckhoff-el1008-ethercat-terminal-8-channel-digital-input-24v-dc-3-ms-input-filter-12-100-68-mm","provider":"Apexon Solutions LLC","version":"1.0","type":"link"}