{"product_id":"beckhoff-kl2012-bus-terminal-digital-output-24v-dc-0-5a-per-channel-2-channels-12-100-68-mm","title":"Beckhoff KL2012 Bus Terminal Digital Output, 24V DC, 0.5A per Channel, 2 Channels, 12×100×68 mm","description":"\u003cdiv\u003e\n  \u003ch2\u003eOverview\u003c\/h2\u003e\n  \u003cp\u003eThe Beckhoff KL2012 is a 2-channel digital output Bus Terminal that switches 24 V DC loads with galvanic isolation from the K‑bus. Each channel supports up to 0.5 A and is protected against overload and short-circuit. Signal states are indicated via front LEDs. Suitable for ohmic, inductive, or lamp loads in modular Bus Terminal systems.\u003c\/p\u003e\n\n  \u003ch3\u003eKey Features\u003c\/h3\u003e\n  \u003cul\u003e\n    \u003cli\u003e2 digital outputs, 24 V DC\u003c\/li\u003e\n    \u003cli\u003e0.5 A per channel, short-circuit proof; breaking energy \u0026lt; 150 mJ\/channel\u003c\/li\u003e\n    \u003cli\u003eSupports ohmic, inductive, and lamp loads\u003c\/li\u003e\n    \u003cli\u003eElectrical isolation: 500 V (K‑bus\/field)\u003c\/li\u003e\n    \u003cli\u003eCompact 12 mm width; per‑channel LED indication\u003c\/li\u003e\n    \u003cli\u003eApprovals: CE, CCC, UL, ATEX, IECEx\u003c\/li\u003e\n  \u003c\/ul\u003e\n\n  \u003ch3\u003eSpecifications\u003c\/h3\u003e\n  \u003ctable style=\"width:100%; border-collapse: collapse; border: 1px solid #e0e0e0; font-size: 14px; margin-top: 10px;\"\u003e\n    \u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n      \u003ctd style=\"padding: 6px 10px; background-color: #f9f9f9; font-weight: bold; width: 35%; color: #333;\"\u003eSpecific MPN\u003c\/td\u003e\n      \u003ctd style=\"padding: 6px 10px; color: #555;\"\u003eKL2012\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n      \u003ctd style=\"padding: 6px 10px; background-color: #f9f9f9; font-weight: bold; width: 35%; color: #333;\"\u003eOutputs\u003c\/td\u003e\n      \u003ctd style=\"padding: 6px 10px; color: #555;\"\u003e2 channels, 24 V DC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n      \u003ctd style=\"padding: 6px 10px; background-color: #f9f9f9; font-weight: bold; width: 35%; color: #333;\"\u003eMax. Output Current\u003c\/td\u003e\n      \u003ctd style=\"padding: 6px 10px; color: #555;\"\u003e0.5 A per channel (short-circuit proof)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n      \u003ctd style=\"padding: 6px 10px; background-color: #f9f9f9; font-weight: bold; width: 35%; color: #333;\"\u003eLoad Types\u003c\/td\u003e\n      \u003ctd style=\"padding: 6px 10px; color: #555;\"\u003eOhmic, inductive, lamp load\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n      \u003ctd style=\"padding: 6px 10px; background-color: #f9f9f9; font-weight: bold; width: 35%; color: #333;\"\u003eElectrical Isolation\u003c\/td\u003e\n      \u003ctd style=\"padding: 6px 10px; color: #555;\"\u003e500 V (K‑bus\/field potential)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n      \u003ctd style=\"padding: 6px 10px; background-color: #f9f9f9; font-weight: bold; width: 35%; color: #333;\"\u003ePower Contacts Consumption\u003c\/td\u003e\n      \u003ctd style=\"padding: 6px 10px; color: #555;\"\u003etyp. 15 mA + load; power contacts up to 10 A\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n      \u003ctd style=\"padding: 6px 10px; background-color: #f9f9f9; font-weight: bold; width: 35%; color: #333;\"\u003eK‑bus Current\u003c\/td\u003e\n      \u003ctd style=\"padding: 6px 10px; color: #555;\"\u003etyp. 5 mA\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n      \u003ctd style=\"padding: 6px 10px; background-color: #f9f9f9; font-weight: bold; width: 35%; color: #333;\"\u003eBreaking Energy\u003c\/td\u003e\n      \u003ctd style=\"padding: 6px 10px; color: #555;\"\u003e\u0026lt; 150 mJ\/channel\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n      \u003ctd style=\"padding: 6px 10px; background-color: #f9f9f9; font-weight: bold; width: 35%; color: #333;\"\u003eDimensions (W × H × D)\u003c\/td\u003e\n      \u003ctd style=\"padding: 6px 10px; color: #555;\"\u003e12 × 100 × 68 mm; IP20\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n","brand":"Beckhoff","offers":[{"title":"Default Title","offer_id":51787197579543,"sku":null,"price":75.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0837\/9210\/1655\/files\/beckhoff-ethernet-module-beckhoff-kl2012-bus-terminal-digital-output-24v-dc-0-5a-per-channel-2-channels-12x100x68-mm-1215894853.png?v=1767930789","url":"https:\/\/www.apexonsupply.com\/products\/beckhoff-kl2012-bus-terminal-digital-output-24v-dc-0-5a-per-channel-2-channels-12-100-68-mm","provider":"Apexon Solutions LLC","version":"1.0","type":"link"}