{"product_id":"fischer-er7620000004-dual-channel-level-control-relay","title":"FISCHER ER7620000004 ER76 Dual-Channel Level Control Relay, 24V AC, 70kΩ","description":"\n\u003cp\u003eThe \u003cstrong\u003eFISCHER ER7620000004\u003c\/strong\u003e is an ER76 dual-channel level control relay manufactured by FISCHER Mess- und Regeltechnik GmbH. Designed for conductive liquid level monitoring and control, this unit operates on a 24V AC, 50\/60 Hz power supply and provides two potential-free relay changeover contacts. It features a factory-set input sensitivity of 70 kΩ, interval level control operation, and LED switching status indicators. The relay is designed for use with compatible FISCHER NK06 conductive level probes.\u003c\/p\u003e\n\n\u003ctable style=\"width: 100%; border-collapse: collapse; border: 1px solid #e0e0e0; font-size: 13px; margin-top: 20px; font-family: sans-serif;\"\u003e\n\u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n\u003ctd style=\"padding: 8px 10px; background-color: #f9f9f9; font-weight: bold; width: 35%; color: #333; line-height: 1.5; vertical-align: top;\"\u003eManufacturer\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 10px; color: #555; line-height: 1.5; vertical-align: top;\"\u003eFISCHER Mess- und Regeltechnik GmbH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n\u003ctd style=\"padding: 8px 10px; background-color: #f9f9f9; font-weight: bold; color: #333;\"\u003eArt.-no.\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 10px; color: #555;\"\u003eER7620000004\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n\u003ctd style=\"padding: 8px 10px; background-color: #f9f9f9; font-weight: bold; color: #333;\"\u003eProduct Series\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 10px; color: #555;\"\u003eER76\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n\u003ctd style=\"padding: 8px 10px; background-color: #f9f9f9; font-weight: bold; color: #333;\"\u003eProduct Type\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 10px; color: #555;\"\u003eDual-Channel Level Control Relay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n\u003ctd style=\"padding: 8px 10px; background-color: #f9f9f9; font-weight: bold; color: #333;\"\u003eSupply Voltage\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 10px; color: #555;\"\u003e24V AC, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n\u003ctd style=\"padding: 8px 10px; background-color: #f9f9f9; font-weight: bold; color: #333;\"\u003ePower Consumption\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 10px; color: #555;\"\u003eMaximum 5 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n\u003ctd style=\"padding: 8px 10px; background-color: #f9f9f9; font-weight: bold; color: #333;\"\u003eInput Sensitivity\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 10px; color: #555;\"\u003e70 kΩ (Factory Set)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n\u003ctd style=\"padding: 8px 10px; background-color: #f9f9f9; font-weight: bold; color: #333;\"\u003eInput Sensitivity Adjustment Range\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 10px; color: #555;\"\u003e0–200 kΩ (Factory Adjustment)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n\u003ctd style=\"padding: 8px 10px; background-color: #f9f9f9; font-weight: bold; color: #333;\"\u003eMinimum Medium Conductivity\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 10px; color: #555;\"\u003e14 µS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n\u003ctd style=\"padding: 8px 10px; background-color: #f9f9f9; font-weight: bold; color: #333;\"\u003eMeasurement Principle\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 10px; color: #555;\"\u003eConductive Level Detection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n\u003ctd style=\"padding: 8px 10px; background-color: #f9f9f9; font-weight: bold; color: #333;\"\u003eControl Function\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 10px; color: #555;\"\u003eInterval (Minimum\/Maximum Level Control)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n\u003ctd style=\"padding: 8px 10px; background-color: #f9f9f9; font-weight: bold; color: #333;\"\u003eNumber of Channels\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 10px; color: #555;\"\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n\u003ctd style=\"padding: 8px 10px; background-color: #f9f9f9; font-weight: bold; color: #333;\"\u003eSwitching Outputs\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 10px; color: #555;\"\u003e2 Potential-Free Changeover Relay Contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n\u003ctd style=\"padding: 8px 10px; background-color: #f9f9f9; font-weight: bold; color: #333;\"\u003eMaximum Switching Voltage\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 10px; color: #555;\"\u003e250V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n\u003ctd style=\"padding: 8px 10px; background-color: #f9f9f9; font-weight: bold; color: #333;\"\u003eMaximum Switching Current\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 10px; color: #555;\"\u003e2 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n\u003ctd style=\"padding: 8px 10px; background-color: #f9f9f9; font-weight: bold; color: #333;\"\u003eLoad Rating (Nameplate)\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 10px; color: #555;\"\u003e250 VA \/ 50 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n\u003ctd style=\"padding: 8px 10px; background-color: #f9f9f9; font-weight: bold; color: #333;\"\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 10px; color: #555;\"\u003e-10°C to +70°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n\u003ctd style=\"padding: 8px 10px; background-color: #f9f9f9; font-weight: bold; color: #333;\"\u003eHousing Protection\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 10px; color: #555;\"\u003eIP40 (Housing); IP20 (Terminals)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n\u003ctd style=\"padding: 8px 10px; background-color: #f9f9f9; font-weight: bold; color: #333;\"\u003eElectrical Connection\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 10px; color: #555;\"\u003eScrew Terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n\u003ctd style=\"padding: 8px 10px; background-color: #f9f9f9; font-weight: bold; color: #333;\"\u003eMounting\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 10px; color: #555;\"\u003eMounting Rail Installation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n\u003ctd style=\"padding: 8px 10px; background-color: #f9f9f9; font-weight: bold; color: #333;\"\u003eDimensions\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 10px; color: #555;\"\u003e68 × 75 × 110 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px 10px; background-color: #f9f9f9; font-weight: bold; color: #333;\"\u003eCompatible Level Probe\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 10px; color: #555;\"\u003eFISCHER NK06 Conductive Level Probe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003cp\u003e\u003cstrong\u003eTypical Applications:\u003c\/strong\u003e The FISCHER ER7620000004 is designed for minimum and maximum liquid level monitoring in tanks and industrial process systems. Applications include water treatment facilities, automatic filling systems, pump dry-run protection, and oil-water separation processes. Its dual-channel configuration enables monitoring and control of two conductive liquid level circuits.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eB2B Sourcing \u0026amp; Replacement Support:\u003c\/strong\u003e Apexon Supply provides sourcing assistance for the FISCHER ER7620000004 ER76 level control relay and related industrial level monitoring components. Before replacement, buyers should verify the 24V AC supply requirement, dual-channel configuration, 70 kΩ input sensitivity, relay contact ratings, and compatibility with the installed conductive level probes. Individual production numbers identify specific units and do not replace the manufacturer article number.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eRequest a Quote:\u003c\/strong\u003e Contact Apexon Supply with \u003cstrong\u003eArt.-no. ER7620000004\u003c\/strong\u003e, required quantity, and application requirements for B2B quotation, replacement sourcing, or industrial procurement support.\u003c\/p\u003e\n","brand":"FISCHER","offers":[{"title":"Default Title","offer_id":68308676378903,"sku":null,"price":1280.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0837\/9210\/1655\/files\/fischer-er7620000004-dual-channel-level-control-relay.png?v=1794444429","url":"https:\/\/www.apexonsupply.com\/products\/fischer-er7620000004-dual-channel-level-control-relay","provider":"Apexon Solutions LLC","version":"1.0","type":"link"}