{"product_id":"mersen-a15qs2-2-amp-trap-a15qs-high-speed-fuse-150vac-150vdc-2a-form","title":"Mersen A15QS2-2 Amp-Trap Form 101 High-Speed Fuse, 2 A, 150 VAC\/DC","description":"\u003cp\u003eThe \u003cstrong\u003eMersen A15QS2-2\u003c\/strong\u003e is an Amp-Trap® Form 101 high-speed fuse rated 2 A at 150 VAC\/DC. Its compact 10 x 38 mm ferrule format is designed for protecting diodes and other semiconductor devices in space-limited applications.\u003c\/p\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; border: 1px solid #e0e0e0; font-size: 13px; margin-top: 20px; font-family: sans-serif;\"\u003e\n\u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n\u003ctd style=\"padding: 8px 10px; background-color: #f9f9f9; font-weight: bold; width: 35%; color: #333; line-height: 1.5; vertical-align: top;\"\u003eCatalog Number\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 10px; color: #555; line-height: 1.5; vertical-align: top;\"\u003eA15QS2-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n\u003ctd style=\"padding: 8px 10px; background-color: #f9f9f9; font-weight: bold; width: 35%; color: #333; line-height: 1.5; vertical-align: top;\"\u003eProduct Family\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 10px; color: #555; line-height: 1.5; vertical-align: top;\"\u003eAmp-Trap® Form 101\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n\u003ctd style=\"padding: 8px 10px; background-color: #f9f9f9; font-weight: bold; width: 35%; color: #333; line-height: 1.5; vertical-align: top;\"\u003eRated Current\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 10px; color: #555; line-height: 1.5; vertical-align: top;\"\u003e2 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n\u003ctd style=\"padding: 8px 10px; background-color: #f9f9f9; font-weight: bold; width: 35%; color: #333; line-height: 1.5; vertical-align: top;\"\u003eRated Voltage\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 10px; color: #555; line-height: 1.5; vertical-align: top;\"\u003e150 VAC\/DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n\u003ctd style=\"padding: 8px 10px; background-color: #f9f9f9; font-weight: bold; width: 35%; color: #333; line-height: 1.5; vertical-align: top;\"\u003eInterrupting Rating\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 10px; color: #555; line-height: 1.5; vertical-align: top;\"\u003e100 kA AC; 50 kA DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n\u003ctd style=\"padding: 8px 10px; background-color: #f9f9f9; font-weight: bold; width: 35%; color: #333; line-height: 1.5; vertical-align: top;\"\u003eMounting Type\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 10px; color: #555; line-height: 1.5; vertical-align: top;\"\u003eFerrule, midget dimensions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n\u003ctd style=\"padding: 8px 10px; background-color: #f9f9f9; font-weight: bold; width: 35%; color: #333; line-height: 1.5; vertical-align: top;\"\u003eDimensions\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 10px; color: #555; line-height: 1.5; vertical-align: top;\"\u003e1.50 x 0.41 in (38.1 x 10.4 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n\u003ctd style=\"padding: 8px 10px; background-color: #f9f9f9; font-weight: bold; width: 35%; color: #333; line-height: 1.5; vertical-align: top;\"\u003eOperating Characteristics\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 10px; color: #555; line-height: 1.5; vertical-align: top;\"\u003eFast acting, current limiting, low I²t\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n\u003ctd style=\"padding: 8px 10px; background-color: #f9f9f9; font-weight: bold; width: 35%; color: #333; line-height: 1.5; vertical-align: top;\"\u003eApproval\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 10px; color: #555; line-height: 1.5; vertical-align: top;\"\u003eUL recognized component, UL File E60314\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003cp\u003eTypical applications include protection of diodes, other semiconductor devices, and heavy-duty devices such as electrochemical rectifiers.\u003c\/p\u003e\n\u003cp\u003eApexon Supply provides B2B sourcing, technical comparison, and replacement support for the Mersen A15QS2-2. Buyers should verify the current rating, voltage rating, interrupting rating, dimensions, and mounting configuration against the original equipment requirements.\u003c\/p\u003e\n\u003cp\u003eSend catalog number \u003cstrong\u003eA15QS2-2\u003c\/strong\u003e, the required quantity, and application requirements for RFQ support. Most qualified RFQs receive a response or quote within 12 hours.\u003c\/p\u003e","brand":"Ferraz Shawmut","offers":[{"title":"1 pcs","offer_id":54548087374103,"sku":null,"price":35.0,"currency_code":"USD","in_stock":true},{"title":"3 pcs","offer_id":54548087406871,"sku":null,"price":90.0,"currency_code":"USD","in_stock":true},{"title":"6 pcs","offer_id":54548087439639,"sku":null,"price":180.0,"currency_code":"USD","in_stock":true},{"title":"12 pcs","offer_id":54548087472407,"sku":null,"price":360.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0837\/9210\/1655\/files\/ferraz-shawmut-general-industrial-fuses-mersen-a15qs2-2-amp-trap-a15qs-high-speed-fuse-150vac-150vdc-2a-form-101-1-5in-x-0-41in-pack-of-10-1215325789.png?v=1767801337","url":"https:\/\/www.apexonsupply.com\/products\/mersen-a15qs2-2-amp-trap-a15qs-high-speed-fuse-150vac-150vdc-2a-form","provider":"Apexon Solutions LLC","version":"1.0","type":"link"}