{"product_id":"mersen-a15qs4-2-amp-trap-a15qs-high-speed-fuse-150vac-150vdc-4a-form-101-1-5in-x-0-41in-pack-of-10","title":"Mersen A15QS4-2 Amp-Trap A15QS High Speed Fuse, 150VAC\/150VDC, 4A, Form 101 1.5in x 0.41in - Pack of 10","description":"\u003cdiv\u003e\n  \u003ch2\u003eOverview\u003c\/h2\u003e\n  \u003cp\u003eThe Mersen A15QS4-2 is a Form 101 high speed ferrule fuse from the Amp-Trap A15QS 150VAC\/150VDC series, designed for the specific protection of diodes and other semiconductor devices rated 150VAC\/DC. Its compact 1.5 in x 0.41 in size is ideal where space is limited. Sold as a pack of 10.\u003c\/p\u003e\n\n  \u003ch3\u003eKey Features\u003c\/h3\u003e\n  \u003cul\u003e\n    \u003cli\u003eHigh speed, current-limiting performance for semiconductor protection\u003c\/li\u003e\n    \u003cli\u003eLow I²t and controlled arc voltage to reduce stress during fault clearing\u003c\/li\u003e\n    \u003cli\u003eFerrule (Form 101) construction for easy clip mounting\u003c\/li\u003e\n    \u003cli\u003eRated 150 VAC \/ 150 VDC\u003c\/li\u003e\n    \u003cli\u003eRoHS compliant\u003c\/li\u003e\n  \u003c\/ul\u003e\n\n  \u003ch3\u003eApplications\u003c\/h3\u003e\n  \u003cul\u003e\n    \u003cli\u003eProtection of diodes and other semiconductor devices at 150 VAC\/DC\u003c\/li\u003e\n    \u003cli\u003eGeneral semiconductor protection where compact ferrule fuses are required\u003c\/li\u003e\n  \u003c\/ul\u003e\n\n  \u003ch3\u003eSpecifications\u003c\/h3\u003e\n  \u003ctable style=\"width:100%; border-collapse: collapse; border: 1px solid #e0e0e0; font-size: 14px; margin-top: 10px;\"\u003e\n    \u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n      \u003ctd style=\"padding: 6px 10px; background-color: #f9f9f9; font-weight: bold; width: 35%; color: #333;\"\u003eItem Number\u003c\/td\u003e\n      \u003ctd style=\"padding: 6px 10px; color: #555;\"\u003eA15QS4-2\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n      \u003ctd style=\"padding: 6px 10px; background-color: #f9f9f9; font-weight: bold; width: 35%; color: #333;\"\u003eSeries\u003c\/td\u003e\n      \u003ctd style=\"padding: 6px 10px; color: #555;\"\u003eAmp-Trap A15QS 150VAC 150VDC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n      \u003ctd style=\"padding: 6px 10px; background-color: #f9f9f9; font-weight: bold; width: 35%; color: #333;\"\u003eDescription\u003c\/td\u003e\n      \u003ctd style=\"padding: 6px 10px; color: #555;\"\u003eHigh Speed Fuse Amp-Trap A15QS 150VAC 150VDC 4A Ferrule\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n      \u003ctd style=\"padding: 6px 10px; background-color: #f9f9f9; font-weight: bold; width: 35%; color: #333;\"\u003eAmpere Rating\u003c\/td\u003e\n      \u003ctd style=\"padding: 6px 10px; color: #555;\"\u003e4 A\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n      \u003ctd style=\"padding: 6px 10px; background-color: #f9f9f9; font-weight: bold; width: 35%; color: #333;\"\u003eRated Voltage (AC)\u003c\/td\u003e\n      \u003ctd style=\"padding: 6px 10px; color: #555;\"\u003e150 V (UL)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n      \u003ctd style=\"padding: 6px 10px; background-color: #f9f9f9; font-weight: bold; width: 35%; color: #333;\"\u003eRated Voltage (DC)\u003c\/td\u003e\n      \u003ctd style=\"padding: 6px 10px; color: #555;\"\u003e150 V (UL)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n      \u003ctd style=\"padding: 6px 10px; background-color: #f9f9f9; font-weight: bold; width: 35%; color: #333;\"\u003eInterrupting Rating (AC)\u003c\/td\u003e\n      \u003ctd style=\"padding: 6px 10px; color: #555;\"\u003e100 kA (per datasheet)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n      \u003ctd style=\"padding: 6px 10px; background-color: #f9f9f9; font-weight: bold; width: 35%; color: #333;\"\u003eInterrupting Rating (DC)\u003c\/td\u003e\n      \u003ctd style=\"padding: 6px 10px; color: #555;\"\u003e50 kA (per datasheet)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n      \u003ctd style=\"padding: 6px 10px; background-color: #f9f9f9; font-weight: bold; width: 35%; color: #333;\"\u003eAC or DC\u003c\/td\u003e\n      \u003ctd style=\"padding: 6px 10px; color: #555;\"\u003eAC\/DC; 50\/60 Hz\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n      \u003ctd style=\"padding: 6px 10px; background-color: #f9f9f9; font-weight: bold; width: 35%; color: #333;\"\u003eSpeed \/ Characteristic\u003c\/td\u003e\n      \u003ctd style=\"padding: 6px 10px; color: #555;\"\u003eHigh Speed (semiconductor protection)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n      \u003ctd style=\"padding: 6px 10px; background-color: #f9f9f9; font-weight: bold; width: 35%; color: #333;\"\u003eMounting\u003c\/td\u003e\n      \u003ctd style=\"padding: 6px 10px; color: #555;\"\u003eClip\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n      \u003ctd style=\"padding: 6px 10px; background-color: #f9f9f9; font-weight: bold; width: 35%; color: #333;\"\u003eConnection \/ Terminal\u003c\/td\u003e\n      \u003ctd style=\"padding: 6px 10px; color: #555;\"\u003eFerrule (Form 101)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n      \u003ctd style=\"padding: 6px 10px; background-color: #f9f9f9; font-weight: bold; width: 35%; color: #333;\"\u003eDimensions\u003c\/td\u003e\n      \u003ctd style=\"padding: 6px 10px; color: #555;\"\u003eLength 1.5 in; Diameter 0.41 in\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n      \u003ctd style=\"padding: 6px 10px; background-color: #f9f9f9; font-weight: bold; width: 35%; color: #333;\"\u003eBody \/ Insulating Material\u003c\/td\u003e\n      \u003ctd style=\"padding: 6px 10px; color: #555;\"\u003eGMG\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n      \u003ctd style=\"padding: 6px 10px; background-color: #f9f9f9; font-weight: bold; width: 35%; color: #333;\"\u003eEAN \/ UPC\u003c\/td\u003e\n      \u003ctd style=\"padding: 6px 10px; color: #555;\"\u003e782001453411\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n      \u003ctd style=\"padding: 6px 10px; background-color: #f9f9f9; font-weight: bold; width: 35%; color: #333;\"\u003eSell Pack Quantity\u003c\/td\u003e\n      \u003ctd style=\"padding: 6px 10px; color: #555;\"\u003e10 pieces\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n      \u003ctd style=\"padding: 6px 10px; background-color: #f9f9f9; font-weight: bold; width: 35%; color: #333;\"\u003eDiscrepancy Notice\u003c\/td\u003e\n      \u003ctd style=\"padding: 6px 10px; color: #555;\"\u003eWebsite lists AC Max I.R. 200 kA; datasheet specifies 100 kA AC and 50 kA DC. Datasheet values are used here.\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n","brand":"Ferraz Shawmut","offers":[{"title":"Default Title","offer_id":51784227389719,"sku":null,"price":150.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0837\/9210\/1655\/files\/ferraz-shawmut-general-industrial-fuses-mersen-a15qs4-2-amp-trap-a15qs-high-speed-fuse-150vac-150vdc-4a-form-101-1-5in-x-0-41in-pack-of-10-1215325787.png?v=1767801278","url":"https:\/\/www.apexonsupply.com\/products\/mersen-a15qs4-2-amp-trap-a15qs-high-speed-fuse-150vac-150vdc-4a-form-101-1-5in-x-0-41in-pack-of-10","provider":"Apexon Solutions LLC","version":"1.0","type":"link"}