{"product_id":"mersen-s215135-fr14am69v6-fuses","title":"Mersen FR14AM69V6 aM Fuse, 690V AC, 6A, 14x51mm","description":"\u003cp\u003eMersen FR14AM69V6 is a am cylindrical fuse rated at 6 A and 690 V AC, size 14x51 mm, for motor and transformer protection (utilization category aM, partial-range). The aM fuse-link has a ceramic body with silver-plated copper contacts and is approved by Lloyd's Register and Bureau Veritas. It handles motor starting currents and transformer inrush currents. It is rated to IEC 60269-1 \u0026amp; -2.\u003c\/p\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; border: 1px solid #e0e0e0; font-size: 13px; margin-top: 20px; font-family: sans-serif;\"\u003e\n\u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n\u003ctd style=\"padding: 8px 10px; background-color: #f9f9f9; font-weight: bold; width: 35%; color: #333; line-height: 1.5; vertical-align: top;\"\u003eBrand\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 10px; color: #555; line-height: 1.5; vertical-align: top;\"\u003eMersen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n\u003ctd style=\"padding: 8px 10px; background-color: #f9f9f9; font-weight: bold; width: 35%; color: #333; line-height: 1.5; vertical-align: top;\"\u003eManufacturer Part Number\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 10px; color: #555; line-height: 1.5; vertical-align: top;\"\u003eFR14AM69V6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n\u003ctd style=\"padding: 8px 10px; background-color: #f9f9f9; font-weight: bold; width: 35%; color: #333; line-height: 1.5; vertical-align: top;\"\u003eItem Number\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 10px; color: #555; line-height: 1.5; vertical-align: top;\"\u003eS215135\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n\u003ctd style=\"padding: 8px 10px; background-color: #f9f9f9; font-weight: bold; width: 35%; color: #333; line-height: 1.5; vertical-align: top;\"\u003eSeries\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 10px; color: #555; line-height: 1.5; vertical-align: top;\"\u003eFR14AM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n\u003ctd style=\"padding: 8px 10px; background-color: #f9f9f9; font-weight: bold; width: 35%; color: #333; line-height: 1.5; vertical-align: top;\"\u003eCategory\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 10px; color: #555; line-height: 1.5; vertical-align: top;\"\u003eaM Cylindrical Fuse\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n\u003ctd style=\"padding: 8px 10px; background-color: #f9f9f9; font-weight: bold; width: 35%; color: #333; line-height: 1.5; vertical-align: top;\"\u003eRated Current\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 10px; color: #555; line-height: 1.5; vertical-align: top;\"\u003e6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n\u003ctd style=\"padding: 8px 10px; background-color: #f9f9f9; font-weight: bold; width: 35%; color: #333; line-height: 1.5; vertical-align: top;\"\u003eRated Voltage (AC)\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 10px; color: #555; line-height: 1.5; vertical-align: top;\"\u003e690 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n\u003ctd style=\"padding: 8px 10px; background-color: #f9f9f9; font-weight: bold; width: 35%; color: #333; line-height: 1.5; vertical-align: top;\"\u003eUtilization Category\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 10px; color: #555; line-height: 1.5; vertical-align: top;\"\u003eaM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n\u003ctd style=\"padding: 8px 10px; background-color: #f9f9f9; font-weight: bold; width: 35%; color: #333; line-height: 1.5; vertical-align: top;\"\u003eFuse Size\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 10px; color: #555; line-height: 1.5; vertical-align: top;\"\u003e14x51 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n\u003ctd style=\"padding: 8px 10px; background-color: #f9f9f9; font-weight: bold; width: 35%; color: #333; line-height: 1.5; vertical-align: top;\"\u003eBreaking Capacity\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 10px; color: #555; line-height: 1.5; vertical-align: top;\"\u003e120 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n\u003ctd style=\"padding: 8px 10px; background-color: #f9f9f9; font-weight: bold; width: 35%; color: #333; line-height: 1.5; vertical-align: top;\"\u003eWatt Losses\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 10px; color: #555; line-height: 1.5; vertical-align: top;\"\u003e0.42 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n\u003ctd style=\"padding: 8px 10px; background-color: #f9f9f9; font-weight: bold; width: 35%; color: #333; line-height: 1.5; vertical-align: top;\"\u003eStandards\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 10px; color: #555; line-height: 1.5; vertical-align: top;\"\u003eIEC 60269-1 \u0026amp; -2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n\u003ctd style=\"padding: 8px 10px; background-color: #f9f9f9; font-weight: bold; width: 35%; color: #333; line-height: 1.5; vertical-align: top;\"\u003eCertifications\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 10px; color: #555; line-height: 1.5; vertical-align: top;\"\u003eLloyd's Register, Bureau Veritas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n\u003ctd style=\"padding: 8px 10px; background-color: #f9f9f9; font-weight: bold; width: 35%; color: #333; line-height: 1.5; vertical-align: top;\"\u003eCompliance\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 10px; color: #555; line-height: 1.5; vertical-align: top;\"\u003eCE, RoHS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n\u003ctd style=\"padding: 8px 10px; background-color: #f9f9f9; font-weight: bold; width: 35%; color: #333; line-height: 1.5; vertical-align: top;\"\u003eWeight\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 10px; color: #555; line-height: 1.5; vertical-align: top;\"\u003e20 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003cp\u003eTypical applications include motor protection, transformer protection, and control circuits where starting currents and inrush currents occur.\u003c\/p\u003e\n\u003cp\u003eApexon Supply provides B2B industrial sourcing and replacement sourcing support for obsolete and hard-to-find parts. Contact Apexon Supply to confirm sourcing options and technical alignment.\u003c\/p\u003e\n\u003cp\u003eRequest a B2B quote for sourcing support. Send the MPN, quantity, and application requirements for RFQ support. Most qualified RFQs receive a response or quote within 12 hours.\u003c\/p\u003e","brand":"Mersen","offers":[{"title":"1 pcs","offer_id":47902687723799,"sku":null,"price":15.0,"currency_code":"USD","in_stock":true},{"title":"3 pcs","offer_id":68487717126423,"sku":null,"price":36.0,"currency_code":"USD","in_stock":true},{"title":"6 pcs","offer_id":68487717159191,"sku":null,"price":57.6,"currency_code":"USD","in_stock":true},{"title":"12 pcs","offer_id":68487717191959,"sku":null,"price":92.16,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0837\/9210\/1655\/files\/mersen-mersen-s215135-fr14am69v6-fuses-10-pieces-1212527807.jpg?v=1766466003","url":"https:\/\/www.apexonsupply.com\/products\/mersen-s215135-fr14am69v6-fuses","provider":"Apexon Solutions LLC","version":"1.0","type":"link"}