{"product_id":"parker-321h35-2995-491514c2-h-series-indirect-acting-solenoid-valve-2-2-way-24v-dc","title":"Parker 321H35-2995-491514C2 H Series Indirect Acting Solenoid Valve, 2\/2-Way, 24V DC","description":"\u003cxml\u003e\n    \u003cp\u003eThe Parker H Series is an indirect acting solenoid valve, offering options for normally closed and open configurations from 1\/4\" to 3\/4\", designed for industrial and process applications. Sold as a single unit.\u003c\/p\u003e\n    \u003ch2\u003eKey Features\u003c\/h2\u003e\n    \u003cul\u003e\n        \u003cli\u003eRobust design with different flow rates\u003c\/li\u003e\n        \u003cli\u003eTemperature range suitable for various mediums including air and neutral gases\u003c\/li\u003e\n        \u003cli\u003eMaximum operating pressure of 40 bar\u003c\/li\u003e\n        \u003cli\u003eSeal material: PUR\u003c\/li\u003e\n    \u003c\/ul\u003e\n    \u003ctable style=\"width:100%; border-collapse: collapse; border: 1px solid #e0e0e0; font-size: 13px; margin-top: 10px;\"\u003e\n        \u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n            \u003ctd style=\"padding: 4px 10px; background-color: #f9f9f9; font-weight: bold; width: 35%; color: #333; line-height: 1.4;\"\u003ePart Number\u003c\/td\u003e\n            \u003ctd style=\"padding: 4px 10px; color: #555; line-height: 1.4;\"\u003e321H35-2995-491514C2\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n            \u003ctd style=\"padding: 4px 10px; background-color: #f9f9f9; font-weight: bold; color: #333; line-height: 1.4;\"\u003eElectrical Connection\u003c\/td\u003e\n            \u003ctd style=\"padding: 4px 10px; color: #555; line-height: 1.4;\"\u003e2 P + E plug according to EN 175301-803 type A\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n            \u003ctd style=\"padding: 4px 10px; background-color: #f9f9f9; font-weight: bold; color: #333; line-height: 1.4;\"\u003eMaximum Operating Pressure\u003c\/td\u003e\n            \u003ctd style=\"padding: 4px 10px; color: #555; line-height: 1.4;\"\u003e40 bar\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n            \u003ctd style=\"padding: 4px 10px; background-color: #f9f9f9; font-weight: bold; color: #333; line-height: 1.4;\"\u003eCoil Specifications Met\u003c\/td\u003e\n            \u003ctd style=\"padding: 4px 10px; color: #555; line-height: 1.4;\"\u003eCE, VDE, UL, EAC\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n            \u003ctd style=\"padding: 4px 10px; background-color: #f9f9f9; font-weight: bold; color: #333; line-height: 1.4;\"\u003eInsulation Class\u003c\/td\u003e\n            \u003ctd style=\"padding: 4px 10px; color: #555; line-height: 1.4;\"\u003eF 155 °C\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n            \u003ctd style=\"padding: 4px 10px; background-color: #f9f9f9; font-weight: bold; color: #333; line-height: 1.4;\"\u003eMedia\u003c\/td\u003e\n            \u003ctd style=\"padding: 4px 10px; color: #555; line-height: 1.4;\"\u003eAir, Neutral Gases, Liquids\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n            \u003ctd style=\"padding: 4px 10px; background-color: #f9f9f9; font-weight: bold; color: #333; line-height: 1.4;\"\u003eFunction\u003c\/td\u003e\n            \u003ctd style=\"padding: 4px 10px; color: #555; line-height: 1.4;\"\u003eNormally closed\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n            \u003ctd style=\"padding: 4px 10px; background-color: #f9f9f9; font-weight: bold; color: #333; line-height: 1.4;\"\u003eMaximum Fluid Temperature\u003c\/td\u003e\n            \u003ctd style=\"padding: 4px 10px; color: #555; line-height: 1.4;\"\u003e50 °C\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n            \u003ctd style=\"padding: 4px 10px; background-color: #f9f9f9; font-weight: bold; color: #333; line-height: 1.4;\"\u003ePower Supply Voltage\u003c\/td\u003e\n            \u003ctd style=\"padding: 4px 10px; color: #555; line-height: 1.4;\"\u003e24V DC\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n            \u003ctd style=\"padding: 4px 10px; background-color: #f9f9f9; font-weight: bold; color: #333; line-height: 1.4;\"\u003eCoil Power Consumption\u003c\/td\u003e\n            \u003ctd style=\"padding: 4px 10px; color: #555; line-height: 1.4;\"\u003e12W\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n            \u003ctd style=\"padding: 4px 10px; background-color: #f9f9f9; font-weight: bold; color: #333; line-height: 1.4;\"\u003ePort Size\u003c\/td\u003e\n            \u003ctd style=\"padding: 4px 10px; color: #555; line-height: 1.4;\"\u003eG 1\/2\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n            \u003ctd style=\"padding: 4px 10px; background-color: #f9f9f9; font-weight: bold; color: #333; line-height: 1.4;\"\u003eSeal Material\u003c\/td\u003e\n            \u003ctd style=\"padding: 4px 10px; color: #555; line-height: 1.4;\"\u003ePUR\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n            \u003ctd style=\"padding: 4px 10px; background-color: #f9f9f9; font-weight: bold; color: #333; line-height: 1.4;\"\u003eValve Type\u003c\/td\u003e\n            \u003ctd style=\"padding: 4px 10px; color: #555; line-height: 1.4;\"\u003e2\/2-Way\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n            \u003ctd style=\"padding: 4px 10px; background-color: #f9f9f9; font-weight: bold; color: #333; line-height: 1.4;\"\u003eActuation Type\u003c\/td\u003e\n            \u003ctd style=\"padding: 4px 10px; color: #555; line-height: 1.4;\"\u003ePilot Operated\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n            \u003ctd style=\"padding: 4px 10px; background-color: #f9f9f9; font-weight: bold; color: #333; line-height: 1.4;\"\u003ePort Type\u003c\/td\u003e\n            \u003ctd style=\"padding: 4px 10px; color: #555; line-height: 1.4;\"\u003ePipe Mounting\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n            \u003ctd style=\"padding: 4px 10px; background-color: #f9f9f9; font-weight: bold; color: #333; line-height: 1.4;\"\u003eBody Material\u003c\/td\u003e\n            \u003ctd style=\"padding: 4px 10px; color: #555; line-height: 1.4;\"\u003eCW 617N UNI EN 12165\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n            \u003ctd style=\"padding: 4px 10px; background-color: #f9f9f9; font-weight: bold; color: #333; line-height: 1.4;\"\u003eSeat Material\u003c\/td\u003e\n            \u003ctd style=\"padding: 4px 10px; color: #555; line-height: 1.4;\"\u003eStainless Steel\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n            \u003ctd style=\"padding: 4px 10px; background-color: #f9f9f9; font-weight: bold; color: #333; line-height: 1.4;\"\u003eOrifice Size\u003c\/td\u003e\n            \u003ctd style=\"padding: 4px 10px; color: #555; line-height: 1.4;\"\u003e15 mm\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n            \u003ctd style=\"padding: 4px 10px; background-color: #f9f9f9; font-weight: bold; color: #333; line-height: 1.4;\"\u003eFlow Coefficient 1\u003c\/td\u003e\n            \u003ctd style=\"padding: 4px 10px; color: #555; line-height: 1.4;\"\u003e60 L\/min\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n            \u003ctd style=\"padding: 4px 10px; background-color: #f9f9f9; font-weight: bold; color: #333; line-height: 1.4;\"\u003eFlow Coefficient 2\u003c\/td\u003e\n            \u003ctd style=\"padding: 4px 10px; color: #555; line-height: 1.4;\"\u003e3.6 m3\/hour\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n            \u003ctd style=\"padding: 4px 10px; background-color: #f9f9f9; font-weight: bold; color: #333; line-height: 1.4;\"\u003eMinimum Operating Pressure\u003c\/td\u003e\n            \u003ctd style=\"padding: 4px 10px; color: #555; line-height: 1.4;\"\u003e1.5 bar\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n            \u003ctd style=\"padding: 4px 10px; background-color: #f9f9f9; font-weight: bold; color: #333; line-height: 1.4;\"\u003eMinimum Fluid Temperature\u003c\/td\u003e\n            \u003ctd style=\"padding: 4px 10px; color: #555; line-height: 1.4;\"\u003e-10 °C\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n            \u003ctd style=\"padding: 4px 10px; background-color: #f9f9f9; font-weight: bold; color: #333; line-height: 1.4;\"\u003eCoil Temperature Range\u003c\/td\u003e\n            \u003ctd style=\"padding: 4px 10px; color: #555; line-height: 1.4;\"\u003e-40 to 50 °C\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n            \u003ctd style=\"padding: 4px 10px; background-color: #f9f9f9; font-weight: bold; color: #333; line-height: 1.4;\"\u003eSpecifications Met\u003c\/td\u003e\n            \u003ctd style=\"padding: 4px 10px; color: #555; line-height: 1.4;\"\u003e-\u003c\/td\u003e\n        \u003c\/tr\u003e\n    \u003c\/table\u003e\n\u003c\/xml\u003e\n","brand":"Parker","offers":[{"title":"Default Title","offer_id":51873440989463,"sku":null,"price":225.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0837\/9210\/1655\/files\/322H75-2995-481865C2.png?v=1769921478","url":"https:\/\/www.apexonsupply.com\/products\/parker-321h35-2995-491514c2-h-series-indirect-acting-solenoid-valve-2-2-way-24v-dc","provider":"Apexon Solutions LLC","version":"1.0","type":"link"}