{"product_id":"saginomiya-sev-series-refrigerant-solenoid-valves-ac110v-ac220v-flare-copper-tube","title":"Saginomiya SEV Series Refrigerant Solenoid Valves, AC110V\/AC220V, Flare \u0026 Copper Tube","description":"\u003cp\u003e\u003cstrong\u003eSaginomiya SEV Series Refrigerant Solenoid Valves\u003c\/strong\u003e are normally closed valves for refrigeration, air-conditioning and related fluid-control applications. This series listing covers 11 specified AC110V and AC220V configurations with flare or direct copper-tube connections, including the SEV-603DYFQ300 short-tube configuration.\u003c\/p\u003e\n\n\u003ctable style=\"width: 100%; border-collapse: collapse; border: 1px solid #e0e0e0; font-size: 13px; margin-top: 20px; font-family: sans-serif;\"\u003e\n\u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n\u003ctd style=\"padding: 8px 10px; background-color: #f9f9f9; font-weight: bold; width: 35%; color: #333; line-height: 1.5; vertical-align: top;\"\u003eValve Function\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 10px; color: #555; line-height: 1.5; vertical-align: top;\"\u003eNormally closed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n\u003ctd style=\"padding: 8px 10px; background-color: #f9f9f9; font-weight: bold; width: 35%; color: #333; line-height: 1.5; vertical-align: top;\"\u003eMaximum Working Pressure\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 10px; color: #555; line-height: 1.5; vertical-align: top;\"\u003e4.2 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n\u003ctd style=\"padding: 8px 10px; background-color: #f9f9f9; font-weight: bold; width: 35%; color: #333; line-height: 1.5; vertical-align: top;\"\u003eMaximum Differential Pressure\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 10px; color: #555; line-height: 1.5; vertical-align: top;\"\u003e2.45 MPa with AC coil\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n\u003ctd style=\"padding: 8px 10px; background-color: #f9f9f9; font-weight: bold; width: 35%; color: #333; line-height: 1.5; vertical-align: top;\"\u003eFluid Temperature\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 10px; color: #555; line-height: 1.5; vertical-align: top;\"\u003e-40 to +125 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n\u003ctd style=\"padding: 8px 10px; background-color: #f9f9f9; font-weight: bold; width: 35%; color: #333; line-height: 1.5; vertical-align: top;\"\u003eAmbient Temperature\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 10px; color: #555; line-height: 1.5; vertical-align: top;\"\u003e-30 to +50 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n\u003ctd style=\"padding: 8px 10px; background-color: #f9f9f9; font-weight: bold; width: 35%; color: #333; line-height: 1.5; vertical-align: top;\"\u003eListed Coil Voltages\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 10px; color: #555; line-height: 1.5; vertical-align: top;\"\u003eAC110V and AC220V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n\u003ctd style=\"padding: 8px 10px; background-color: #f9f9f9; font-weight: bold; width: 35%; color: #333; line-height: 1.5; vertical-align: top;\"\u003eSupply Frequency\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 10px; color: #555; line-height: 1.5; vertical-align: top;\"\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n\u003ctd style=\"padding: 8px 10px; background-color: #f9f9f9; font-weight: bold; width: 35%; color: #333; line-height: 1.5; vertical-align: top;\"\u003eCoil Insulation\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 10px; color: #555; line-height: 1.5; vertical-align: top;\"\u003eClass B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ctable style=\"width: 100%; border-collapse: collapse; border: 1px solid #e0e0e0; font-size: 13px; margin-top: 20px; font-family: sans-serif;\"\u003e\n\u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n\u003ctd style=\"padding: 8px 10px; background-color: #f9f9f9; font-weight: bold; width: 35%; color: #333; line-height: 1.5; vertical-align: top;\"\u003eModel and Voltage\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 10px; color: #555; line-height: 1.5; vertical-align: top;\"\u003e\u003cstrong\u003eVerified Configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n\u003ctd style=\"padding: 8px 10px; background-color: #f9f9f9; font-weight: bold; width: 35%; color: #333; line-height: 1.5; vertical-align: top;\"\u003eSEV-502BYF — AC110V\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 10px; color: #555; line-height: 1.5; vertical-align: top;\"\u003eFlare connection; 1\/4 in tube O.D.; 5 mm orifice; Cv 0.51; filter included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n\u003ctd style=\"padding: 8px 10px; background-color: #f9f9f9; font-weight: bold; width: 35%; color: #333; line-height: 1.5; vertical-align: top;\"\u003eSEV-502BYF — AC220V\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 10px; color: #555; line-height: 1.5; vertical-align: top;\"\u003eFlare connection; 1\/4 in tube O.D.; 5 mm orifice; Cv 0.51; filter included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n\u003ctd style=\"padding: 8px 10px; background-color: #f9f9f9; font-weight: bold; width: 35%; color: #333; line-height: 1.5; vertical-align: top;\"\u003eSEV-603BYF — AC110V\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 10px; color: #555; line-height: 1.5; vertical-align: top;\"\u003eFlare connection; 3\/8 in tube O.D.; 6 mm orifice; Cv 0.80; filter included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n\u003ctd style=\"padding: 8px 10px; background-color: #f9f9f9; font-weight: bold; width: 35%; color: #333; line-height: 1.5; vertical-align: top;\"\u003eSEV-603BYF — AC220V\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 10px; color: #555; line-height: 1.5; vertical-align: top;\"\u003eFlare connection; 3\/8 in tube O.D.; 6 mm orifice; Cv 0.80; filter included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n\u003ctd style=\"padding: 8px 10px; background-color: #f9f9f9; font-weight: bold; width: 35%; color: #333; line-height: 1.5; vertical-align: top;\"\u003eSEV-1004BYF — AC220V\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 10px; color: #555; line-height: 1.5; vertical-align: top;\"\u003eFlare connection; 1\/2 in tube O.D.; 10 mm orifice; Cv 1.75; filter included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n\u003ctd style=\"padding: 8px 10px; background-color: #f9f9f9; font-weight: bold; width: 35%; color: #333; line-height: 1.5; vertical-align: top;\"\u003eSEV-1205BYF — AC220V\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 10px; color: #555; line-height: 1.5; vertical-align: top;\"\u003eFlare connection; 5\/8 in tube O.D.; 12 mm orifice; Cv 2.90; filter included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n\u003ctd style=\"padding: 8px 10px; background-color: #f9f9f9; font-weight: bold; width: 35%; color: #333; line-height: 1.5; vertical-align: top;\"\u003eSEV-603DYF — AC220V\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 10px; color: #555; line-height: 1.5; vertical-align: top;\"\u003eDirect copper-tube connection; 3\/8 in tube O.D.; 6 mm orifice; Cv 0.83; no filter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n\u003ctd style=\"padding: 8px 10px; background-color: #f9f9f9; font-weight: bold; width: 35%; color: #333; line-height: 1.5; vertical-align: top;\"\u003eSEV-1004DYF — AC220V\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 10px; color: #555; line-height: 1.5; vertical-align: top;\"\u003eDirect copper-tube connection; 1\/2 in tube O.D.; 10 mm orifice; Cv 2.00; no filter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n\u003ctd style=\"padding: 8px 10px; background-color: #f9f9f9; font-weight: bold; width: 35%; color: #333; line-height: 1.5; vertical-align: top;\"\u003eSEV-1205DYF — AC220V\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 10px; color: #555; line-height: 1.5; vertical-align: top;\"\u003eDirect copper-tube connection; 5\/8 in tube O.D.; 12 mm orifice; Cv 3.50; no filter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n\u003ctd style=\"padding: 8px 10px; background-color: #f9f9f9; font-weight: bold; width: 35%; color: #333; line-height: 1.5; vertical-align: top;\"\u003eSEV-1506DYF — AC220V\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 10px; color: #555; line-height: 1.5; vertical-align: top;\"\u003eDirect copper-tube connection; 3\/4 in tube O.D.; 15 mm orifice; Cv 5.30; no filter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n\u003ctd style=\"padding: 8px 10px; background-color: #f9f9f9; font-weight: bold; width: 35%; color: #333; line-height: 1.5; vertical-align: top;\"\u003eSEV-603DYFQ300 — AC220V\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 10px; color: #555; line-height: 1.5; vertical-align: top;\"\u003eDirect copper-tube Q300 short-tube configuration; 3\/8 in tube O.D.; 6 mm orifice; Cv 0.83; no filter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003cp\u003e\u003cstrong\u003eTypical applications:\u003c\/strong\u003e The SEV Series is designed for refrigeration, air-conditioning and related fluid-control systems. The supplied technical data identifies refrigerants including R22, R134a, R404A, R407C, R410A, R448A and R449A. Confirm refrigerant compatibility and operating conditions before selection.\u003c\/p\u003e\n\n\u003cp\u003eApexon Supply provides B2B sourcing, technical alignment and replacement support for Saginomiya SEV Series refrigerant solenoid valves. Verify the complete valve model, coil voltage, frequency, termination style, ingress-protection requirement and connection configuration against the equipment specification.\u003c\/p\u003e\n\n\u003cp\u003eFor an RFQ, submit the required SEV model, AC110V or AC220V coil voltage, refrigerant, operating pressure, pressure differential, coil termination, quantity and accessory requirements.\u003c\/p\u003e","brand":"Saginomiya","offers":[{"title":"SEV-502BYF AC110V 1\/4","offer_id":54583489986839,"sku":null,"price":65.0,"currency_code":"USD","in_stock":true},{"title":"SEV-502BYF AC220V 1\/4","offer_id":54583490019607,"sku":null,"price":50.0,"currency_code":"USD","in_stock":true},{"title":"SEV-603BYF AC110V 3\/8","offer_id":54583490052375,"sku":null,"price":50.0,"currency_code":"USD","in_stock":true},{"title":"SEV-603BYF AC220V 3\/8","offer_id":54583490085143,"sku":null,"price":50.0,"currency_code":"USD","in_stock":true},{"title":"SEV-1004BYF AC220V 1\/2","offer_id":54583490117911,"sku":null,"price":100.0,"currency_code":"USD","in_stock":true},{"title":"SEV-1205BYF AC220V 5\/8","offer_id":54583490150679,"sku":null,"price":120.0,"currency_code":"USD","in_stock":true},{"title":"SEV-603DYF AC220V 3\/8","offer_id":54583490183447,"sku":null,"price":50.0,"currency_code":"USD","in_stock":true},{"title":"SEV-1004DYF AC220V 1\/2","offer_id":54583499456791,"sku":null,"price":100.0,"currency_code":"USD","in_stock":true},{"title":"SEV-1205DYF AC220V 5\/8","offer_id":54583499489559,"sku":null,"price":120.0,"currency_code":"USD","in_stock":true},{"title":"SEV-1506DYF AC220V 3\/4","offer_id":54583499522327,"sku":null,"price":125.0,"currency_code":"USD","in_stock":true},{"title":"SEV-603DYFQ300 AC220V 3\/8","offer_id":54583499555095,"sku":null,"price":50.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0837\/9210\/1655\/files\/SEV-502BYFAC220V.png?v=1785575906","url":"https:\/\/www.apexonsupply.com\/products\/saginomiya-sev-series-refrigerant-solenoid-valves-ac110v-ac220v-flare-copper-tube","provider":"Apexon Solutions LLC","version":"1.0","type":"link"}