{"product_id":"saginomiya-sys-series-single-function-pressure-controls-x2-kgf-cm-scale-automatic-reset","title":"Saginomiya SYS Series Single Function Pressure Controls, X2 kgf\/cm² Scale, Automatic Reset","description":"\u003cp\u003e\u003cstrong\u003eSaginomiya SYS Series Single Function Pressure Controls\u003c\/strong\u003e are automatic-reset refrigerant pressure controls with an IP20 enclosure and 7\/16-20UNF pressure connection. This family page covers catalog numbers \u003cstrong\u003eSYS-C106X2\u003c\/strong\u003e, \u003cstrong\u003eSYS-C110X2\u003c\/strong\u003e, \u003cstrong\u003eSYS-C130X2\u003c\/strong\u003e and \u003cstrong\u003eSYS-C140X2\u003c\/strong\u003e. The X2 catalog-number suffix identifies a kgf\/cm² scale display.\u003c\/p\u003e\n\n\u003ctable style=\"width: 100%; border-collapse: collapse; border: 1px solid #e0e0e0; font-size: 13px; margin-top: 20px; font-family: sans-serif;\"\u003e\n\u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n\u003ctd style=\"padding: 8px 10px; background-color: #f9f9f9; font-weight: bold; width: 35%; color: #333; line-height: 1.5; vertical-align: top;\"\u003eControl Type\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 10px; color: #555; line-height: 1.5; vertical-align: top;\"\u003eSingle function pressure control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n\u003ctd style=\"padding: 8px 10px; background-color: #f9f9f9; font-weight: bold; width: 35%; color: #333; line-height: 1.5; vertical-align: top;\"\u003eReset Type\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 10px; color: #555; line-height: 1.5; vertical-align: top;\"\u003eAutomatic reset\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n\u003ctd style=\"padding: 8px 10px; background-color: #f9f9f9; font-weight: bold; width: 35%; color: #333; line-height: 1.5; vertical-align: top;\"\u003eScale Unit\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 10px; color: #555; line-height: 1.5; vertical-align: top;\"\u003ekgf\/cm², catalog suffix X2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n\u003ctd style=\"padding: 8px 10px; background-color: #f9f9f9; font-weight: bold; width: 35%; color: #333; line-height: 1.5; vertical-align: top;\"\u003eEnclosure\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 10px; color: #555; line-height: 1.5; vertical-align: top;\"\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n\u003ctd style=\"padding: 8px 10px; background-color: #f9f9f9; font-weight: bold; width: 35%; color: #333; line-height: 1.5; vertical-align: top;\"\u003ePressure Connection\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 10px; color: #555; line-height: 1.5; vertical-align: top;\"\u003e7\/16-20UNF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n\u003ctd style=\"padding: 8px 10px; background-color: #f9f9f9; font-weight: bold; width: 35%; color: #333; line-height: 1.5; vertical-align: top;\"\u003eFluid Temperature\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 10px; color: #555; line-height: 1.5; vertical-align: top;\"\u003e-20 to 120 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n\u003ctd style=\"padding: 8px 10px; background-color: #f9f9f9; font-weight: bold; width: 35%; color: #333; line-height: 1.5; vertical-align: top;\"\u003eAmbient Temperature\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 10px; color: #555; line-height: 1.5; vertical-align: top;\"\u003e-20 to 70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n\u003ctd style=\"padding: 8px 10px; background-color: #f9f9f9; font-weight: bold; width: 35%; color: #333; line-height: 1.5; vertical-align: top;\"\u003eElectrical Rating\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 10px; color: #555; line-height: 1.5; vertical-align: top;\"\u003e125\/250 V AC; 12 A non-inductive; 0.75 A inductive full load; 72 A inrush\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n\u003ctd style=\"padding: 8px 10px; background-color: #f9f9f9; font-weight: bold; width: 35%; color: #333; line-height: 1.5; vertical-align: top;\"\u003eMinimum Contact Capacity\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 10px; color: #555; line-height: 1.5; vertical-align: top;\"\u003e50 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n\u003ctd style=\"padding: 8px 10px; background-color: #f9f9f9; font-weight: bold; width: 35%; color: #333; line-height: 1.5; vertical-align: top;\"\u003eContact Function\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 10px; color: #555; line-height: 1.5; vertical-align: top;\"\u003eTerminal 1 common; terminal 3 closes on pressure increase; terminal 5 closes on pressure decrease\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n\u003ctd style=\"padding: 8px 10px; background-color: #f9f9f9; font-weight: bold; width: 35%; color: #333; line-height: 1.5; vertical-align: top;\"\u003eReference Dimensions\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 10px; color: #555; line-height: 1.5; vertical-align: top;\"\u003e75 mm wide; 86.5 mm overall height; 48 mm depth\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ctable style=\"width: 100%; border-collapse: collapse; border: 1px solid #e0e0e0; font-size: 13px; margin-top: 20px; font-family: sans-serif;\"\u003e\n\u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n\u003ctd style=\"padding: 8px 10px; background-color: #f9f9f9; font-weight: bold; width: 35%; color: #333; line-height: 1.5; vertical-align: top;\"\u003eCatalog Number\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 10px; color: #555; line-height: 1.5; vertical-align: top;\"\u003e\u003cstrong\u003eVerified Model Parameters\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n\u003ctd style=\"padding: 8px 10px; background-color: #f9f9f9; font-weight: bold; width: 35%; color: #333; line-height: 1.5; vertical-align: top;\"\u003eSYS-C106X2\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 10px; color: #555; line-height: 1.5; vertical-align: top;\"\u003eR404A, R407C, R134a and R22; range -0.06 MPa (-50 cmHg) to 0.6 MPa (6 kgf\/cm²); differential 0.06 to 0.4 MPa (0.6 to 4 kgf\/cm²); factory settings 0.2 MPa (2 kgf\/cm²) Off (On) and 0.3 MPa (3 kgf\/cm²) On (Off); maximum working pressure 1.65 MPa (16.5 kgf\/cm²)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n\u003ctd style=\"padding: 8px 10px; background-color: #f9f9f9; font-weight: bold; width: 35%; color: #333; line-height: 1.5; vertical-align: top;\"\u003eSYS-C110X2\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 10px; color: #555; line-height: 1.5; vertical-align: top;\"\u003eR404A, R407C, R134a and R22; range 0.1 to 1 MPa (1 to 10 kgf\/cm²); differential 0.1 to 0.3 MPa (1 to 3 kgf\/cm²); factory settings 0.4 MPa (4 kgf\/cm²) Off (On) and 0.6 MPa (6 kgf\/cm²) On (Off); maximum working pressure 1.65 MPa (16.5 kgf\/cm²)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n\u003ctd style=\"padding: 8px 10px; background-color: #f9f9f9; font-weight: bold; width: 35%; color: #333; line-height: 1.5; vertical-align: top;\"\u003eSYS-C130X2\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 10px; color: #555; line-height: 1.5; vertical-align: top;\"\u003eR404A, R407C, R134a and R22; range 0.5 to 3 MPa (5 to 30 kgf\/cm²); differential 0.3 to 1 MPa (3 to 10 kgf\/cm²); factory settings 1.5 MPa (15 kgf\/cm²) Off (On) and 2 MPa (20 kgf\/cm²) On (Off); maximum working pressure 3.3 MPa (33 kgf\/cm²)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n\u003ctd style=\"padding: 8px 10px; background-color: #f9f9f9; font-weight: bold; width: 35%; color: #333; line-height: 1.5; vertical-align: top;\"\u003eSYS-C140X2\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 10px; color: #555; line-height: 1.5; vertical-align: top;\"\u003eApplicable to R410A; range 1 to 4.3 MPa (10 to 43 kgf\/cm²); differential 0.5 to 1 MPa (5 to 10 kgf\/cm²); factory settings 2 MPa (20 kgf\/cm²) Off (On) and 2.5 MPa (25 kgf\/cm²) On (Off); maximum working pressure 4.7 MPa (47 kgf\/cm²)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003cp\u003e\u003cstrong\u003eRefrigerant selection:\u003c\/strong\u003e SYS-C106X2, SYS-C110X2 and SYS-C130X2 are specified for R404A, R407C, R134a and R22. SYS-C140X2 is the listed R410A configuration. Models other than SYS-C140X2 should not be selected for R410A service.\u003c\/p\u003e\n\n\u003cp\u003eApexon Supply provides B2B sourcing, replacement sourcing and technical-alignment support for Saginomiya SYS Series pressure controls. Confirm the catalog number, refrigerant, pressure range, differential range, factory switching values and electrical requirements before replacement.\u003c\/p\u003e\n\n\u003cp\u003eFor an RFQ, submit SYS-C106X2, SYS-C110X2, SYS-C130X2 or SYS-C140X2 with the required quantity, refrigerant and operating-pressure details. Most qualified RFQs receive a response or quote within 12 hours.\u003c\/p\u003e","brand":"Saginomiya","offers":[{"title":"SYS-C106X2 6 kgf\/cm2","offer_id":54586099663127,"sku":null,"price":35.0,"currency_code":"USD","in_stock":true},{"title":"SYS-C110X2 10 kgf\/cm2","offer_id":54586099695895,"sku":null,"price":35.0,"currency_code":"USD","in_stock":true},{"title":"SYS-C130X2 30 kgf\/cm2","offer_id":54586099728663,"sku":null,"price":35.0,"currency_code":"USD","in_stock":true},{"title":"SYS-C140X2 43 kgf\/cm2","offer_id":54586099761431,"sku":null,"price":35.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0837\/9210\/1655\/files\/SYS-C106X2.webp?v=1785638382","url":"https:\/\/www.apexonsupply.com\/products\/saginomiya-sys-series-single-function-pressure-controls-x2-kgf-cm-scale-automatic-reset","provider":"Apexon Solutions LLC","version":"1.0","type":"link"}