{"product_id":"schneider-a9f74432-acti9-ic60n-miniature-circuit-breaker-4p-32a-c-curve","title":"Schneider A9F74432 Acti9 iC60N Miniature Circuit Breaker, 4P, 32A, C Curve","description":"\u003cp\u003eThe Schneider Electric A9F74432 is a high-performance Acti9 iC60N miniature circuit breaker designed for robust electrical distribution and protection in industrial and commercial environments. This 4-pole, 32A device features a C-curve tripping characteristic and thermal-magnetic technology, ensuring reliable overcurrent and short-circuit protection across both AC and DC networks.\u003c\/p\u003e\n\n\u003ctable style=\"width: 100%; border-collapse: collapse; border: 1px solid #e0e0e0; font-size: 13px; margin-top: 20px; font-family: sans-serif;\"\u003e\n  \u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n    \u003ctd style=\"padding: 8px 10px; background-color: #f9f9f9; font-weight: bold; width: 35%; color: #333; line-height: 1.5; vertical-align: top;\"\u003eProduct ID (MPN)\u003c\/td\u003e\n    \u003ctd style=\"padding: 8px 10px; color: #555; line-height: 1.5; vertical-align: top;\"\u003eA9F74432\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n    \u003ctd style=\"padding: 8px 10px; background-color: #f9f9f9; font-weight: bold; width: 35%; color: #333; line-height: 1.5; vertical-align: top;\"\u003eRange\u003c\/td\u003e\n    \u003ctd style=\"padding: 8px 10px; color: #555; line-height: 1.5; vertical-align: top;\"\u003eActi9 iC60\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n    \u003ctd style=\"padding: 8px 10px; background-color: #f9f9f9; font-weight: bold; width: 35%; color: #333; line-height: 1.5; vertical-align: top;\"\u003ePoles Description\u003c\/td\u003e\n    \u003ctd style=\"padding: 8px 10px; color: #555; line-height: 1.5; vertical-align: top;\"\u003e4P\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n    \u003ctd style=\"padding: 8px 10px; background-color: #f9f9f9; font-weight: bold; width: 35%; color: #333; line-height: 1.5; vertical-align: top;\"\u003eRated Current [In]\u003c\/td\u003e\n    \u003ctd style=\"padding: 8px 10px; color: #555; line-height: 1.5; vertical-align: top;\"\u003e32 A\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n    \u003ctd style=\"padding: 8px 10px; background-color: #f9f9f9; font-weight: bold; width: 35%; color: #333; line-height: 1.5; vertical-align: top;\"\u003eCurve Code\u003c\/td\u003e\n    \u003ctd style=\"padding: 8px 10px; color: #555; line-height: 1.5; vertical-align: top;\"\u003eC\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n    \u003ctd style=\"padding: 8px 10px; background-color: #f9f9f9; font-weight: bold; width: 35%; color: #333; line-height: 1.5; vertical-align: top;\"\u003eBreaking Capacity\u003c\/td\u003e\n    \u003ctd style=\"padding: 8px 10px; color: #555; line-height: 1.5; vertical-align: top;\"\u003e6000 A Icn at 400 V AC conforming to EN\/IEC 60898-1; 10 kA Icu at 380...415 V AC conforming to EN\/IEC 60947-2\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n    \u003ctd style=\"padding: 8px 10px; background-color: #f9f9f9; font-weight: bold; width: 35%; color: #333; line-height: 1.5; vertical-align: top;\"\u003eNetwork Type\u003c\/td\u003e\n    \u003ctd style=\"padding: 8px 10px; color: #555; line-height: 1.5; vertical-align: top;\"\u003eAC \/ DC\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n    \u003ctd style=\"padding: 8px 10px; background-color: #f9f9f9; font-weight: bold; width: 35%; color: #333; line-height: 1.5; vertical-align: top;\"\u003eRated Operational Voltage [Ue]\u003c\/td\u003e\n    \u003ctd style=\"padding: 8px 10px; color: #555; line-height: 1.5; vertical-align: top;\"\u003e400 V AC 50\/60 Hz; \u0026lt;= 250 V DC\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n    \u003ctd style=\"padding: 8px 10px; background-color: #f9f9f9; font-weight: bold; width: 35%; color: #333; line-height: 1.5; vertical-align: top;\"\u003eMagnetic Tripping Limit\u003c\/td\u003e\n    \u003ctd style=\"padding: 8px 10px; color: #555; line-height: 1.5; vertical-align: top;\"\u003e8 x In +\/- 20 %\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n    \u003ctd style=\"padding: 8px 10px; background-color: #f9f9f9; font-weight: bold; width: 35%; color: #333; line-height: 1.5; vertical-align: top;\"\u003eIP Degree of Protection\u003c\/td\u003e\n    \u003ctd style=\"padding: 8px 10px; color: #555; line-height: 1.5; vertical-align: top;\"\u003eIP20 conforming to IEC 60529\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n    \u003ctd style=\"padding: 8px 10px; background-color: #f9f9f9; font-weight: bold; width: 35%; color: #333; line-height: 1.5; vertical-align: top;\"\u003eMounting Mode\u003c\/td\u003e\n    \u003ctd style=\"padding: 8px 10px; color: #555; line-height: 1.5; vertical-align: top;\"\u003eClip-on (35 mm DIN rail)\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n    \u003ctd style=\"padding: 8px 10px; background-color: #f9f9f9; font-weight: bold; width: 35%; color: #333; line-height: 1.5; vertical-align: top;\"\u003eDimensions (H x W x D)\u003c\/td\u003e\n    \u003ctd style=\"padding: 8px 10px; color: #555; line-height: 1.5; vertical-align: top;\"\u003e85 mm x 72 mm x 78.5 mm\u003c\/td\u003e\n  \u003c\/tr\u003e\n\u003c\/table\u003e","brand":"Schneider","offers":[{"title":"1 pcs","offer_id":52559430779159,"sku":null,"price":150.0,"currency_code":"USD","in_stock":true},{"title":"2 pcs","offer_id":52559430811927,"sku":null,"price":290.0,"currency_code":"USD","in_stock":true},{"title":"3 pcs","offer_id":52559430844695,"sku":null,"price":435.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0837\/9210\/1655\/files\/Schneider_A9F74432_Miniature_Circuit_Breaker_-_32A_C-Curve_4P_-_Front_Perspective.jpg?v=1774659240","url":"https:\/\/www.apexonsupply.com\/products\/schneider-a9f74432-acti9-ic60n-miniature-circuit-breaker-4p-32a-c-curve","provider":"Apexon Solutions LLC","version":"1.0","type":"link"}