{"product_id":"schneider-electric-eocrss-05s-eocr-series-electronic-overcurrent-relay-0-5-6a-220v-ac","title":"Schneider Electric EOCRSS-05S EOCR Series Electronic Overcurrent Relay, 0.5-6A, 220V AC","description":"\u003cp\u003e\u003cstrong\u003eSchneider Electric EOCRSS-05S\u003c\/strong\u003e is an EOCR-series electronic overcurrent protection relay for monitoring and protecting motor loads. It provides an adjustable current range of 0.5–6 A, operates from a 220 V AC supply, and includes a 7-segment LED display for status indication.\u003c\/p\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; border: 1px solid #e0e0e0; font-size: 13px; margin-top: 20px; font-family: sans-serif;\"\u003e\n\u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n\u003ctd style=\"padding: 8px 10px; background-color: #f9f9f9; font-weight: bold; width: 35%; color: #333; line-height: 1.5; vertical-align: top;\"\u003eBrand\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 10px; color: #555; line-height: 1.5; vertical-align: top;\"\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n\u003ctd style=\"padding: 8px 10px; background-color: #f9f9f9; font-weight: bold; width: 35%; color: #333; line-height: 1.5; vertical-align: top;\"\u003eManufacturer Part Number\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 10px; color: #555; line-height: 1.5; vertical-align: top;\"\u003eEOCRSS-05S\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n\u003ctd style=\"padding: 8px 10px; background-color: #f9f9f9; font-weight: bold; width: 35%; color: #333; line-height: 1.5; vertical-align: top;\"\u003eSeries\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 10px; color: #555; line-height: 1.5; vertical-align: top;\"\u003eEOCR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n\u003ctd style=\"padding: 8px 10px; background-color: #f9f9f9; font-weight: bold; width: 35%; color: #333; line-height: 1.5; vertical-align: top;\"\u003eProduct Type\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 10px; color: #555; line-height: 1.5; vertical-align: top;\"\u003eElectronic overcurrent protection relay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n\u003ctd style=\"padding: 8px 10px; background-color: #f9f9f9; font-weight: bold; width: 35%; color: #333; line-height: 1.5; vertical-align: top;\"\u003eProtection Adjustment Range\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 10px; color: #555; line-height: 1.5; vertical-align: top;\"\u003e0.5–6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n\u003ctd style=\"padding: 8px 10px; background-color: #f9f9f9; font-weight: bold; width: 35%; color: #333; line-height: 1.5; vertical-align: top;\"\u003eTripping Threshold\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 10px; color: #555; line-height: 1.5; vertical-align: top;\"\u003e0.5–6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n\u003ctd style=\"padding: 8px 10px; background-color: #f9f9f9; font-weight: bold; width: 35%; color: #333; line-height: 1.5; vertical-align: top;\"\u003eRated Supply Voltage\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 10px; color: #555; line-height: 1.5; vertical-align: top;\"\u003e220 V AC, 50–60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n\u003ctd style=\"padding: 8px 10px; background-color: #f9f9f9; font-weight: bold; width: 35%; color: #333; line-height: 1.5; vertical-align: top;\"\u003eProtection Functions\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 10px; color: #555; line-height: 1.5; vertical-align: top;\"\u003eOverload, phase loss, phase reversal, locked rotor, and 50% phase unbalance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n\u003ctd style=\"padding: 8px 10px; background-color: #f9f9f9; font-weight: bold; width: 35%; color: #333; line-height: 1.5; vertical-align: top;\"\u003eContact Configuration\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 10px; color: #555; line-height: 1.5; vertical-align: top;\"\u003e1 NO + 1 NC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n\u003ctd style=\"padding: 8px 10px; background-color: #f9f9f9; font-weight: bold; width: 35%; color: #333; line-height: 1.5; vertical-align: top;\"\u003eReset Type\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 10px; color: #555; line-height: 1.5; vertical-align: top;\"\u003eManual reset or electrical interruption, 0–1 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n\u003ctd style=\"padding: 8px 10px; background-color: #f9f9f9; font-weight: bold; width: 35%; color: #333; line-height: 1.5; vertical-align: top;\"\u003eDisplay Type\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 10px; color: #555; line-height: 1.5; vertical-align: top;\"\u003e7-segment LED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n\u003ctd style=\"padding: 8px 10px; background-color: #f9f9f9; font-weight: bold; width: 35%; color: #333; line-height: 1.5; vertical-align: top;\"\u003eMounting Support\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 10px; color: #555; line-height: 1.5; vertical-align: top;\"\u003e35 mm DIN rail or panel mounting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n\u003ctd style=\"padding: 8px 10px; background-color: #f9f9f9; font-weight: bold; width: 35%; color: #333; line-height: 1.5; vertical-align: top;\"\u003eDimensions\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 10px; color: #555; line-height: 1.5; vertical-align: top;\"\u003e71 x 70 x 68 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eTypical applications:\u003c\/strong\u003e Motor control centers, automation panels, industrial machinery, and motor protection circuits requiring adjustable overcurrent and phase-fault monitoring.\u003c\/p\u003e\n\u003cp\u003eApexon Supply provides B2B sourcing and replacement support for Schneider Electric EOCRSS-05S. Verify the 0.5–6 A adjustment range, 220 V AC supply, protection functions, contact configuration, mounting method, and dimensions before replacement.\u003c\/p\u003e\n\u003cp\u003eSend the MPN, required quantity, motor ratings, and application requirements to request a B2B quote and technical alignment support.\u003c\/p\u003e","brand":"Schneider","offers":[{"title":"Default Title","offer_id":52273191616791,"sku":null,"price":80.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0837\/9210\/1655\/files\/EOCRDS3-05S.png?v=1770980708","url":"https:\/\/www.apexonsupply.com\/products\/schneider-electric-eocrss-05s-eocr-series-electronic-overcurrent-relay-0-5-6a-220v-ac","provider":"Apexon Solutions LLC","version":"1.0","type":"link"}