{"product_id":"schneider-electric-evr-1p22-electronic-voltage-relay-single-phase-ac-dc-100-240vac-dc-control-100-240v-monitoring-over-under-volt-50-60hz","title":"Schneider Electric EVR-1P22 Electronic Voltage Relay, Single-Phase AC\/DC, 100-240VAC\/DC Control, 100-240V Monitoring, Over\/Under Volt, 50\/60Hz","description":"\u003cdiv\u003e\n    \u003ch2\u003eOverview\u003c\/h2\u003e\n    \u003cp\u003eThe EVR-1P22 is a voltage protection relay designed to provide accurate DC\/AC voltage measurement and protection. It features over\/under voltage protection, fail-safe operation, and has an IP20 protection rating.\u003c\/p\u003e\n    \u003ch2\u003eKey Features\u003c\/h2\u003e\n    \u003cul\u003e\n        \u003cli\u003eVoltage Measurement Precision: ±2%\u003c\/li\u003e\n        \u003cli\u003eFail-safe Option: N\/R\u003c\/li\u003e\n        \u003cli\u003eAutomatic Reset Capability\u003c\/li\u003e\n        \u003cli\u003eProtection Rating: IP20\u003c\/li\u003e\n    \u003c\/ul\u003e\n    \u003ch2\u003eSpecifications\u003c\/h2\u003e\n    \u003ctable style=\"width:100%; border-collapse: collapse; border: 1px solid #e0e0e0; font-size: 13px; margin-top: 10px;\"\u003e\n        \u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n            \u003ctd style=\"padding: 4px 10px; background-color: #f9f9f9; font-weight: bold; width: 35%; color: #333; line-height: 1.4;\"\u003eModel\u003c\/td\u003e\n            \u003ctd style=\"padding: 4px 10px; color: #555; line-height: 1.4;\"\u003eEVR-1P22\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n            \u003ctd style=\"padding: 4px 10px; background-color: #f9f9f9; font-weight: bold; width: 35%; color: #333; line-height: 1.4;\"\u003eVoltage Range\u003c\/td\u003e\n            \u003ctd style=\"padding: 4px 10px; color: #555; line-height: 1.4;\"\u003e100…300V AC\/DC\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n            \u003ctd style=\"padding: 4px 10px; background-color: #f9f9f9; font-weight: bold; width: 35%; color: #333; line-height: 1.4;\"\u003eOver Voltage Setting\u003c\/td\u003e\n            \u003ctd style=\"padding: 4px 10px; color: #555; line-height: 1.4;\"\u003e5, 10, 15, 20, 25%, Off\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n            \u003ctd style=\"padding: 4px 10px; background-color: #f9f9f9; font-weight: bold; width: 35%; color: #333; line-height: 1.4;\"\u003eUnder Voltage Setting\u003c\/td\u003e\n            \u003ctd style=\"padding: 4px 10px; color: #555; line-height: 1.4;\"\u003e-5, -10, -15, -20, -25, -30%, Off\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n            \u003ctd style=\"padding: 4px 10px; background-color: #f9f9f9; font-weight: bold; width: 35%; color: #333; line-height: 1.4;\"\u003eOperation Delay Time\u003c\/td\u003e\n            \u003ctd style=\"padding: 4px 10px; color: #555; line-height: 1.4;\"\u003e0.2, 1, 3, 5, 7, 10s\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n            \u003ctd style=\"padding: 4px 10px; background-color: #f9f9f9; font-weight: bold; width: 35%; color: #333; line-height: 1.4;\"\u003eReset Time\u003c\/td\u003e\n            \u003ctd style=\"padding: 4px 10px; color: #555; line-height: 1.4;\"\u003e0.5, 1, 5, 10, 20, 30s, Off\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n            \u003ctd style=\"padding: 4px 10px; background-color: #f9f9f9; font-weight: bold; width: 35%; color: #333; line-height: 1.4;\"\u003eOperating Temperature\u003c\/td\u003e\n            \u003ctd style=\"padding: 4px 10px; color: #555; line-height: 1.4;\"\u003e-20...60˚C\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n            \u003ctd style=\"padding: 4px 10px; background-color: #f9f9f9; font-weight: bold; width: 35%; color: #333; line-height: 1.4;\"\u003eDimensions (W x D x H)\u003c\/td\u003e\n            \u003ctd style=\"padding: 4px 10px; color: #555; line-height: 1.4;\"\u003e62 x 89.5 x 75 mm\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n            \u003ctd style=\"padding: 4px 10px; background-color: #f9f9f9; font-weight: bold; width: 35%; color: #333; line-height: 1.4;\"\u003eWeight\u003c\/td\u003e\n            \u003ctd style=\"padding: 4px 10px; color: #555; line-height: 1.4;\"\u003e163g\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n            \u003ctd style=\"padding: 4px 10px; background-color: #f9f9f9; font-weight: bold; width: 35%; color: #333; line-height: 1.4;\"\u003eMounting\u003c\/td\u003e\n            \u003ctd style=\"padding: 4px 10px; color: #555; line-height: 1.4;\"\u003ePanel or 35mm DIN-rail\u003c\/td\u003e\n        \u003c\/tr\u003e\n    \u003c\/table\u003e\n\u003c\/div\u003e\n","brand":"Schneider","offers":[{"title":"Default Title","offer_id":51645087973655,"sku":null,"price":120.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0837\/9210\/1655\/files\/schneider-schneider-electric-evr-1p22-electronic-voltage-relay-single-phase-ac-dc-100-240vac-dc-control-100-240v-monitoring-over-under-volt-50-60hz-1212524414.png?v=1766329201","url":"https:\/\/www.apexonsupply.com\/products\/schneider-electric-evr-1p22-electronic-voltage-relay-single-phase-ac-dc-100-240vac-dc-control-100-240v-monitoring-over-under-volt-50-60hz","provider":"Apexon Solutions LLC","version":"1.0","type":"link"}