{"product_id":"schneider-gv2-me14c-6-0-10a-motor-circuit-breaker","title":"Schneider Electric GV2ME14C TeSys GV2 Motor Circuit Breaker, 6.0-10A Thermal Setting, 3P","description":"\u003cp\u003eThe Schneider Electric GV2ME14C is a robust 3-pole thermal-magnetic motor circuit breaker designed for the manual control and protection of industrial motors. Featuring integrated push-button operation and a wide thermal adjustment range of 6 to 10 Amperes, this TeSys series device ensures reliable protection against overloads and short circuits in demanding AC network environments.\u003c\/p\u003e\n\n\u003ctable width=\"100%\" style=\"border-collapse: collapse; border: 1px solid #e0e0e0; font-size: 13px; margin-top: 20px; font-family: sans-serif;\"\u003e\n  \u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n    \u003ctd style=\"padding: 8px 10px; background-color: #f9f9f9; font-weight: bold; width: 35%; color: #333; line-height: 1.5; vertical-align: top;\"\u003eProduct ID (MPN)\u003c\/td\u003e\n    \u003ctd style=\"padding: 8px 10px; color: #555; line-height: 1.5; vertical-align: top;\"\u003eGV2ME14C\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n    \u003ctd style=\"padding: 8px 10px; background-color: #f9f9f9; font-weight: bold; width: 35%; color: #333; line-height: 1.5; vertical-align: top;\"\u003eProduct Family\u003c\/td\u003e\n    \u003ctd style=\"padding: 8px 10px; color: #555; line-height: 1.5; vertical-align: top;\"\u003eTeSys GV2\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n    \u003ctd style=\"padding: 8px 10px; background-color: #f9f9f9; font-weight: bold; width: 35%; color: #333; line-height: 1.5; vertical-align: top;\"\u003eThermal Protection Range\u003c\/td\u003e\n    \u003ctd style=\"padding: 8px 10px; color: #555; line-height: 1.5; vertical-align: top;\"\u003e6...10 A\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n    \u003ctd style=\"padding: 8px 10px; background-color: #f9f9f9; font-weight: bold; width: 35%; color: #333; line-height: 1.5; vertical-align: top;\"\u003eMagnetic Tripping Current\u003c\/td\u003e\n    \u003ctd style=\"padding: 8px 10px; color: #555; line-height: 1.5; vertical-align: top;\"\u003e138 A\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n    \u003ctd style=\"padding: 8px 10px; background-color: #f9f9f9; font-weight: bold; width: 35%; color: #333; line-height: 1.5; vertical-align: top;\"\u003eBreaking Capacity (Icu)\u003c\/td\u003e\n    \u003ctd style=\"padding: 8px 10px; color: #555; line-height: 1.5; vertical-align: top;\"\u003e100 kA @ 400\/415 V AC\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n    \u003ctd style=\"padding: 8px 10px; background-color: #f9f9f9; font-weight: bold; width: 35%; color: #333; line-height: 1.5; vertical-align: top;\"\u003eRated Operational Voltage\u003c\/td\u003e\n    \u003ctd style=\"padding: 8px 10px; color: #555; line-height: 1.5; vertical-align: top;\"\u003e690 V AC 50\/60 Hz\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n    \u003ctd style=\"padding: 8px 10px; background-color: #f9f9f9; font-weight: bold; width: 35%; color: #333; line-height: 1.5; vertical-align: top;\"\u003eControl Type\u003c\/td\u003e\n    \u003ctd style=\"padding: 8px 10px; color: #555; line-height: 1.5; vertical-align: top;\"\u003ePush-button\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n    \u003ctd style=\"padding: 8px 10px; background-color: #f9f9f9; font-weight: bold; width: 35%; color: #333; line-height: 1.5; vertical-align: top;\"\u003ePhase Failure Sensitivity\u003c\/td\u003e\n    \u003ctd style=\"padding: 8px 10px; color: #555; line-height: 1.5; vertical-align: top;\"\u003eYes conforming to IEC 60947-4-1\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n    \u003ctd style=\"padding: 8px 10px; background-color: #f9f9f9; font-weight: bold; width: 35%; color: #333; line-height: 1.5; vertical-align: top;\"\u003eIP Degree of Protection\u003c\/td\u003e\n    \u003ctd style=\"padding: 8px 10px; color: #555; line-height: 1.5; vertical-align: top;\"\u003eIP20 conforming to IEC 60529\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n    \u003ctd style=\"padding: 8px 10px; background-color: #f9f9f9; font-weight: bold; width: 35%; color: #333; line-height: 1.5; vertical-align: top;\"\u003eMounting Mode\u003c\/td\u003e\n    \u003ctd style=\"padding: 8px 10px; color: #555; line-height: 1.5; vertical-align: top;\"\u003eRail (35 mm DIN rail) \/ Clips\u003c\/td\u003e\n  \u003c\/tr\u003e\n\u003c\/table\u003e","brand":"Schneider","offers":[{"title":"1 pcs","offer_id":52541383901463,"sku":null,"price":40.0,"currency_code":"USD","in_stock":true},{"title":"3 pcs","offer_id":52541383934231,"sku":null,"price":115.0,"currency_code":"USD","in_stock":true},{"title":"6 pcs","offer_id":52541383966999,"sku":null,"price":225.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0837\/9210\/1655\/files\/VFDDXmSB9vJ8UbY0wGEPa_6mo8B7hf.jpg?v=1779714599","url":"https:\/\/www.apexonsupply.com\/products\/schneider-gv2-me14c-6-0-10a-motor-circuit-breaker","provider":"Apexon Solutions LLC","version":"1.0","type":"link"}