{"product_id":"schneider-lc1d126-contactor","title":"Schneider LC1D126 TeSys Deca Contactors, 3-Pole 25A AC-1 12A AC-3, AC\/DC Coil Models M7, F7, E7, B7, MDC, FDC, EDC, BDC","description":"\u003cp\u003eThe Schneider Electric LC1D126 TeSys Deca contactor is a high-performance electrical control device engineered for switching motors and inductive loads. Designed for reliability and precision, this 3-pole contactor supports up to 12A AC-3 and 25A AC-1 ratings, ensuring seamless operation for industrial machinery across varied enterprise power environments.\u003c\/p\u003e\n\n\u003ctable width=\"100%\" style=\"border-collapse: collapse; border: 1px solid #e0e0e0; font-size: 13px; margin-top: 20px; font-family: sans-serif;\"\u003e\n  \u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n    \u003ctd style=\"padding: 8px 10px; background-color: #f9f9f9; font-weight: bold; width: 35%; color: #333; line-height: 1.5; vertical-align: top;\"\u003eProduct ID (MPN)\u003c\/td\u003e\n    \u003ctd style=\"padding: 8px 10px; color: #555; line-height: 1.5; vertical-align: top;\"\u003eLC1D126 Series\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n    \u003ctd style=\"padding: 8px 10px; background-color: #f9f9f9; font-weight: bold; width: 35%; color: #333; line-height: 1.5; vertical-align: top;\"\u003eAvailable Coil Variants\u003c\/td\u003e\n    \u003ctd style=\"padding: 8px 10px; color: #555; line-height: 1.5; vertical-align: top;\"\u003eM7C (220VAC), F7C (110VAC), E7C (48VAC), B7C (24VAC), MDC (220VDC), FDC (110VDC), EDC (48VDC), BDC (24VDC)\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n    \u003ctd style=\"padding: 8px 10px; background-color: #f9f9f9; font-weight: bold; width: 35%; color: #333; line-height: 1.5; vertical-align: top;\"\u003ePole Configuration\u003c\/td\u003e\n    \u003ctd style=\"padding: 8px 10px; color: #555; line-height: 1.5; vertical-align: top;\"\u003e3-Pole (3 NO)\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n    \u003ctd style=\"padding: 8px 10px; background-color: #f9f9f9; font-weight: bold; width: 35%; color: #333; line-height: 1.5; vertical-align: top;\"\u003eRated Operational Current\u003c\/td\u003e\n    \u003ctd style=\"padding: 8px 10px; color: #555; line-height: 1.5; vertical-align: top;\"\u003e25 A (AC-1) \/ 12 A (AC-3) at \u0026lt;= 440 V\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n    \u003ctd style=\"padding: 8px 10px; background-color: #f9f9f9; font-weight: bold; width: 35%; color: #333; line-height: 1.5; vertical-align: top;\"\u003eMotor Power (kW)\u003c\/td\u003e\n    \u003ctd style=\"padding: 8px 10px; color: #555; line-height: 1.5; vertical-align: top;\"\u003e5.5 kW at 380...415 V AC 50\/60 Hz\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n    \u003ctd style=\"padding: 8px 10px; background-color: #f9f9f9; font-weight: bold; width: 35%; color: #333; line-height: 1.5; vertical-align: top;\"\u003eAuxiliary Contacts\u003c\/td\u003e\n    \u003ctd style=\"padding: 8px 10px; color: #555; line-height: 1.5; vertical-align: top;\"\u003e1 NO + 1 NC Integrated\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n    \u003ctd style=\"padding: 8px 10px; background-color: #f9f9f9; font-weight: bold; width: 35%; color: #333; line-height: 1.5; vertical-align: top;\"\u003eRated Insulation Voltage (Ui)\u003c\/td\u003e\n    \u003ctd style=\"padding: 8px 10px; color: #555; line-height: 1.5; vertical-align: top;\"\u003e690 V conforming to IEC 60947-4-1\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n    \u003ctd style=\"padding: 8px 10px; background-color: #f9f9f9; font-weight: bold; width: 35%; color: #333; line-height: 1.5; vertical-align: top;\"\u003eTightening Torque\u003c\/td\u003e\n    \u003ctd style=\"padding: 8px 10px; color: #555; line-height: 1.5; vertical-align: top;\"\u003eControl: 1.7 N.m \/ Power: 1.7 N.m\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n    \u003ctd style=\"padding: 8px 10px; background-color: #f9f9f9; font-weight: bold; width: 35%; color: #333; line-height: 1.5; vertical-align: top;\"\u003eMechanical Durability\u003c\/td\u003e\n    \u003ctd style=\"padding: 8px 10px; color: #555; line-height: 1.5; vertical-align: top;\"\u003e15 Mcycles\u003c\/td\u003e\n  \u003c\/tr\u003e\n\u003c\/table\u003e","brand":"Schneider","offers":[{"title":"M7C AC220V","offer_id":48348972515607,"sku":null,"price":40.0,"currency_code":"USD","in_stock":true},{"title":"F7C  AC110V","offer_id":48348972548375,"sku":null,"price":40.0,"currency_code":"USD","in_stock":true},{"title":"E7C AC48V","offer_id":48348972581143,"sku":null,"price":40.0,"currency_code":"USD","in_stock":true},{"title":"B7C AC24V","offer_id":48348972613911,"sku":null,"price":40.0,"currency_code":"USD","in_stock":true},{"title":"MDC DC220V","offer_id":48348972646679,"sku":null,"price":50.0,"currency_code":"USD","in_stock":true},{"title":"FDC DC110V","offer_id":48348972679447,"sku":null,"price":50.0,"currency_code":"USD","in_stock":true},{"title":"EDC DC48V","offer_id":48348972712215,"sku":null,"price":50.0,"currency_code":"USD","in_stock":true},{"title":"BDC DC24V","offer_id":48348972744983,"sku":null,"price":50.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0837\/9210\/1655\/files\/Schneider_LC1D126_TeSys_Deca_Contactor_-_12A_3-Pole_Motor_Starter_-_Front_View_Coil_Selection.png?v=1774348586","url":"https:\/\/www.apexonsupply.com\/products\/schneider-lc1d126-contactor","provider":"Apexon Solutions LLC","version":"1.0","type":"link"}