{"product_id":"schneider-tesys-f-lc1f225m7-220v-ac-contactor","title":"Schneider LC1F225M7 Contactor, 225 A AC-3, 220 V AC 40-400 Hz Coil","description":"\u003cp\u003eThe Schneider LC1F225M7 is a TeSys F 3-pole (3 NO) contactor rated 225 A (AC-3 at ≤440 V), with a 220 V AC 40-400 Hz coil, for industrial motor control and resistive load switching.\u003c\/p\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; border: 1px solid #e0e0e0; font-size: 13px; margin-top: 20px; font-family: sans-serif;\"\u003e\n\u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n\u003ctd style=\"padding: 8px 10px; background-color: #f9f9f9; font-weight: bold; width: 35%; color: #333; line-height: 1.5; vertical-align: top;\"\u003eModel\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 10px; color: #555; line-height: 1.5; vertical-align: top;\"\u003eLC1F225M7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n\u003ctd style=\"padding: 8px 10px; background-color: #f9f9f9; font-weight: bold; width: 35%; color: #333; line-height: 1.5; vertical-align: top;\"\u003ePoles\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 10px; color: #555; line-height: 1.5; vertical-align: top;\"\u003e3P (3 NO)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n\u003ctd style=\"padding: 8px 10px; background-color: #f9f9f9; font-weight: bold; width: 35%; color: #333; line-height: 1.5; vertical-align: top;\"\u003eUtilization Categories\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 10px; color: #555; line-height: 1.5; vertical-align: top;\"\u003eAC-3, AC-4, AC-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n\u003ctd style=\"padding: 8px 10px; background-color: #f9f9f9; font-weight: bold; width: 35%; color: #333; line-height: 1.5; vertical-align: top;\"\u003eRated Operational Current AC-3\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 10px; color: #555; line-height: 1.5; vertical-align: top;\"\u003e225 A at ≤440 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n\u003ctd style=\"padding: 8px 10px; background-color: #f9f9f9; font-weight: bold; width: 35%; color: #333; line-height: 1.5; vertical-align: top;\"\u003eRated Operational Current AC-1\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 10px; color: #555; line-height: 1.5; vertical-align: top;\"\u003e315 A at ≤440 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n\u003ctd style=\"padding: 8px 10px; background-color: #f9f9f9; font-weight: bold; width: 35%; color: #333; line-height: 1.5; vertical-align: top;\"\u003eRated Operational Voltage\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 10px; color: #555; line-height: 1.5; vertical-align: top;\"\u003e≤690 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n\u003ctd style=\"padding: 8px 10px; background-color: #f9f9f9; font-weight: bold; width: 35%; color: #333; line-height: 1.5; vertical-align: top;\"\u003eControl Circuit Voltage\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 10px; color: #555; line-height: 1.5; vertical-align: top;\"\u003e220 V AC 40-400 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n\u003ctd style=\"padding: 8px 10px; background-color: #f9f9f9; font-weight: bold; width: 35%; color: #333; line-height: 1.5; vertical-align: top;\"\u003eRated Insulation Voltage\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 10px; color: #555; line-height: 1.5; vertical-align: top;\"\u003e1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n\u003ctd style=\"padding: 8px 10px; background-color: #f9f9f9; font-weight: bold; width: 35%; color: #333; line-height: 1.5; vertical-align: top;\"\u003eConventional Free-Air Thermal Current\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 10px; color: #555; line-height: 1.5; vertical-align: top;\"\u003e315 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n\u003ctd style=\"padding: 8px 10px; background-color: #f9f9f9; font-weight: bold; width: 35%; color: #333; line-height: 1.5; vertical-align: top;\"\u003eRated Breaking Capacity\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 10px; color: #555; line-height: 1.5; vertical-align: top;\"\u003e1800 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n\u003ctd style=\"padding: 8px 10px; background-color: #f9f9f9; font-weight: bold; width: 35%; color: #333; line-height: 1.5; vertical-align: top;\"\u003eMechanical Durability\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 10px; color: #555; line-height: 1.5; vertical-align: top;\"\u003e10 Mcycles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n\u003ctd style=\"padding: 8px 10px; background-color: #f9f9f9; font-weight: bold; width: 35%; color: #333; line-height: 1.5; vertical-align: top;\"\u003eMotor Power AC-3\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 10px; color: #555; line-height: 1.5; vertical-align: top;\"\u003e110 kW at 380-440 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n\u003ctd style=\"padding: 8px 10px; background-color: #f9f9f9; font-weight: bold; width: 35%; color: #333; line-height: 1.5; vertical-align: top;\"\u003eWeight\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 10px; color: #555; line-height: 1.5; vertical-align: top;\"\u003e4.75 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n\u003ctd style=\"padding: 8px 10px; background-color: #f9f9f9; font-weight: bold; width: 35%; color: #333; line-height: 1.5; vertical-align: top;\"\u003eDimensions\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 10px; color: #555; line-height: 1.5; vertical-align: top;\"\u003e197 x 168.5 x 181 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003cp\u003eThe contactor switches motors and resistive loads in industrial control applications.\u003c\/p\u003e\n\u003cp\u003eApexon Supply provides B2B sourcing and replacement support for Schneider LC1F225M7 to assist industrial buyers with procurement review and technical alignment.\u003c\/p\u003e\n\u003cp\u003eSend LC1F225M7, required quantity, and application requirements for RFQ support.\u003c\/p\u003e","brand":"Schneider","offers":[{"title":"Default Title","offer_id":51645790257431,"sku":null,"price":400.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0837\/9210\/1655\/files\/schneider-lc1f225p7-contactor.png?v=1795436086","url":"https:\/\/www.apexonsupply.com\/products\/schneider-tesys-f-lc1f225m7-220v-ac-contactor","provider":"Apexon Solutions LLC","version":"1.0","type":"link"}