{"product_id":"siba-20a-700v-5014006-ar-fuses-10-pieces","title":"SIBA 50 140 06.20 URZ Cylindrical Fuse-Link, 20A, 690V\/700V AC, gR, Ø 22x58mm (10 Pieces)","description":"\u003cp\u003eThe SIBA 50 140 06.20 is a premium URZ series cylindrical fuse-link engineered for high-performance protection of industrial semiconductors and power electronics. Operating within the gR characteristic class for reliable, rapid fault clearing, this precise 22x58mm component delivers an impressive rated breaking capacity of 200 kA at 700V AC. Designed without a striker assembly, it complies with major international metrology and electrical standards including DIN EN 60269-4 and UL 248-13, ensuring seamless integration into mission-critical enterprise switchgear.\u003c\/p\u003e\n\n\u003ctable width=\"100%\" style=\"border-collapse: collapse; border: 1px solid #e0e0e0; font-size: 13px; margin-top: 20px; font-family: sans-serif;\"\u003e\n  \u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n    \u003ctd style=\"padding: 8px 10px; background-color: #f9f9f9; font-weight: bold; width: 35%; color: #333; line-height: 1.5; vertical-align: top;\"\u003eProduct ID (MPN)\u003c\/td\u003e\n    \u003ctd style=\"padding: 8px 10px; color: #555; line-height: 1.5; vertical-align: top;\"\u003e50 140 06.20\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n    \u003ctd style=\"padding: 8px 10px; background-color: #f9f9f9; font-weight: bold; width: 35%; color: #333; line-height: 1.5; vertical-align: top;\"\u003eProduct Series\u003c\/td\u003e\n    \u003ctd style=\"padding: 8px 10px; color: #555; line-height: 1.5; vertical-align: top;\"\u003eURZ\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n    \u003ctd style=\"padding: 8px 10px; background-color: #f9f9f9; font-weight: bold; width: 35%; color: #333; line-height: 1.5; vertical-align: top;\"\u003eFuse Type\u003c\/td\u003e\n    \u003ctd style=\"padding: 8px 10px; color: #555; line-height: 1.5; vertical-align: top;\"\u003eCylindrical Fuse-Link\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n    \u003ctd style=\"padding: 8px 10px; background-color: #f9f9f9; font-weight: bold; width: 35%; color: #333; line-height: 1.5; vertical-align: top;\"\u003eRated Current\u003c\/td\u003e\n    \u003ctd style=\"padding: 8px 10px; color: #555; line-height: 1.5; vertical-align: top;\"\u003e20 A\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n    \u003ctd style=\"padding: 8px 10px; background-color: #f9f9f9; font-weight: bold; width: 35%; color: #333; line-height: 1.5; vertical-align: top;\"\u003eRated Voltage\u003c\/td\u003e\n    \u003ctd style=\"padding: 8px 10px; color: #555; line-height: 1.5; vertical-align: top;\"\u003e690 V \/ 700 V AC\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n    \u003ctd style=\"padding: 8px 10px; background-color: #f9f9f9; font-weight: bold; width: 35%; color: #333; line-height: 1.5; vertical-align: top;\"\u003eOperating Class\u003c\/td\u003e\n    \u003ctd style=\"padding: 8px 10px; color: #555; line-height: 1.5; vertical-align: top;\"\u003egR (≤ 100A Models)\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n    \u003ctd style=\"padding: 8px 10px; background-color: #f9f9f9; font-weight: bold; width: 35%; color: #333; line-height: 1.5; vertical-align: top;\"\u003eDimensions \/ Size\u003c\/td\u003e\n    \u003ctd style=\"padding: 8px 10px; color: #555; line-height: 1.5; vertical-align: top;\"\u003eØ 22 x 58 mm\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n    \u003ctd style=\"padding: 8px 10px; background-color: #f9f9f9; font-weight: bold; width: 35%; color: #333; line-height: 1.5; vertical-align: top;\"\u003eRated Breaking Capacity\u003c\/td\u003e\n    \u003ctd style=\"padding: 8px 10px; color: #555; line-height: 1.5; vertical-align: top;\"\u003e200 kA (AC 700 V)\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n    \u003ctd style=\"padding: 8px 10px; background-color: #f9f9f9; font-weight: bold; width: 35%; color: #333; line-height: 1.5; vertical-align: top;\"\u003ePre-Arcing I²t-Value\u003c\/td\u003e\n    \u003ctd style=\"padding: 8px 10px; color: #555; line-height: 1.5; vertical-align: top;\"\u003e21 A²s\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n    \u003ctd style=\"padding: 8px 10px; background-color: #f9f9f9; font-weight: bold; width: 35%; color: #333; line-height: 1.5; vertical-align: top;\"\u003eTotal I²t-Value\u003c\/td\u003e\n    \u003ctd style=\"padding: 8px 10px; color: #555; line-height: 1.5; vertical-align: top;\"\u003e91 A²s (@ AC 660 V)\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n    \u003ctd style=\"padding: 8px 10px; background-color: #f9f9f9; font-weight: bold; width: 35%; color: #333; line-height: 1.5; vertical-align: top;\"\u003ePower Loss\u003c\/td\u003e\n    \u003ctd style=\"padding: 8px 10px; color: #555; line-height: 1.5; vertical-align: top;\"\u003e6.0 W\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n    \u003ctd style=\"padding: 8px 10px; background-color: #f9f9f9; font-weight: bold; width: 35%; color: #333; line-height: 1.5; vertical-align: top;\"\u003eIndicator \/ Striker\u003c\/td\u003e\n    \u003ctd style=\"padding: 8px 10px; color: #555; line-height: 1.5; vertical-align: top;\"\u003eWithout striker\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n    \u003ctd style=\"padding: 8px 10px; background-color: #f9f9f9; font-weight: bold; width: 35%; color: #333; line-height: 1.5; vertical-align: top;\"\u003eApprovals \u0026amp; Standards\u003c\/td\u003e\n    \u003ctd style=\"padding: 8px 10px; color: #555; line-height: 1.5; vertical-align: top;\"\u003eDIN EN 60269-4, IEC 60269-4, VDE 0636-4, UL 248-13\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n    \u003ctd style=\"padding: 8px 10px; background-color: #f9f9f9; font-weight: bold; width: 35%; color: #333; line-height: 1.5; vertical-align: top;\"\u003eWeight\u003c\/td\u003e\n    \u003ctd style=\"padding: 8px 10px; color: #555; line-height: 1.5; vertical-align: top;\"\u003e0.06 kg\u003c\/td\u003e\n  \u003c\/tr\u003e\n\u003c\/table\u003e","brand":"Siba","offers":[{"title":"Default Title","offer_id":49925009375511,"sku":null,"price":190.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0837\/9210\/1655\/files\/siba-siba-50a-700v-5014006-ar-fuses-10-pieces-1212525355.png?v=1766338325","url":"https:\/\/www.apexonsupply.com\/products\/siba-20a-700v-5014006-ar-fuses-10-pieces","provider":"Apexon Solutions LLC","version":"1.0","type":"link"}