{"product_id":"sinofuse-tsa1485-k21500vdc-32a-14x85m-fuse-holder","title":"SINOFUSE TSA1485-K2 1500VDC 32A 14X85M Fuse Holder","description":"\u003cp\u003eThe Sinofuse TSA1485-K2 is a high-performance, 2-pole photovoltaic fuse holder designed to provide reliable overcurrent and short-circuit protection in high-voltage solar utility and industrial DC power systems. Engineered for 14x85mm cartridge fuses, this robust disconnector features a finger-safe IP20 rating, a high impulse withstand voltage of 12 kV, and compliance with stringent global standards including UL 4248-1 and IEC 60947-3. Its durable, flame-retardant UL94-V0 housing ensures safe, long-term operation in demanding solar combiners and distribution boxes.\u003c\/p\u003e\n\n\u003ctable width=\"100%\" style=\"border-collapse: collapse; border: 1px solid #e0e0e0; font-size: 13px; margin-top: 20px; font-family: sans-serif;\"\u003e\n  \u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n    \u003ctd style=\"padding: 8px 10px; background-color: #f9f9f9; font-weight: bold; width: 35%; color: #333; line-height: 1.5; vertical-align: top;\"\u003eProduct ID (MPN)\u003c\/td\u003e\n    \u003ctd style=\"padding: 8px 10px; color: #555; line-height: 1.5; vertical-align: top;\"\u003eTSA1485-K2\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n    \u003ctd style=\"padding: 8px 10px; background-color: #f9f9f9; font-weight: bold; width: 35%; color: #333; line-height: 1.5; vertical-align: top;\"\u003eOrder Code\u003c\/td\u003e\n    \u003ctd style=\"padding: 8px 10px; color: #555; line-height: 1.5; vertical-align: top;\"\u003eTSA1485-K2\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n    \u003ctd style=\"padding: 8px 10px; background-color: #f9f9f9; font-weight: bold; width: 35%; color: #333; line-height: 1.5; vertical-align: top;\"\u003eManufacturer\u003c\/td\u003e\n    \u003ctd style=\"padding: 8px 10px; color: #555; line-height: 1.5; vertical-align: top;\"\u003eXi'an Sinofuse Electric Co., Ltd.\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n    \u003ctd style=\"padding: 8px 10px; background-color: #f9f9f9; font-weight: bold; width: 35%; color: #333; line-height: 1.5; vertical-align: top;\"\u003eNumber of Poles\u003c\/td\u003e\n    \u003ctd style=\"padding: 8px 10px; color: #555; line-height: 1.5; vertical-align: top;\"\u003e2-Pole (2P)\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n    \u003ctd style=\"padding: 8px 10px; background-color: #f9f9f9; font-weight: bold; width: 35%; color: #333; line-height: 1.5; vertical-align: top;\"\u003eCompatible Fuse Size\u003c\/td\u003e\n    \u003ctd style=\"padding: 8px 10px; color: #555; line-height: 1.5; vertical-align: top;\"\u003e14 x 85 mm\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n    \u003ctd style=\"padding: 8px 10px; background-color: #f9f9f9; font-weight: bold; width: 35%; color: #333; line-height: 1.5; vertical-align: top;\"\u003eRated Operational Current (Ie)\u003c\/td\u003e\n    \u003ctd style=\"padding: 8px 10px; color: #555; line-height: 1.5; vertical-align: top;\"\u003e40 A\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n    \u003ctd style=\"padding: 8px 10px; background-color: #f9f9f9; font-weight: bold; width: 35%; color: #333; line-height: 1.5; vertical-align: top;\"\u003eRated Operational Voltage (Ue)\u003c\/td\u003e\n    \u003ctd style=\"padding: 8px 10px; color: #555; line-height: 1.5; vertical-align: top;\"\u003e1500 VDC (DC-20B)\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n    \u003ctd style=\"padding: 8px 10px; background-color: #f9f9f9; font-weight: bold; width: 35%; color: #333; line-height: 1.5; vertical-align: top;\"\u003eRated Insulation Voltage (Ui)\u003c\/td\u003e\n    \u003ctd style=\"padding: 8px 10px; color: #555; line-height: 1.5; vertical-align: top;\"\u003e1600 V\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n    \u003ctd style=\"padding: 8px 10px; background-color: #f9f9f9; font-weight: bold; width: 35%; color: #333; line-height: 1.5; vertical-align: top;\"\u003eRated Impulse Withstand Voltage (Uimp)\u003c\/td\u003e\n    \u003ctd style=\"padding: 8px 10px; color: #555; line-height: 1.5; vertical-align: top;\"\u003e12 kV\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n    \u003ctd style=\"padding: 8px 10px; background-color: #f9f9f9; font-weight: bold; width: 35%; color: #333; line-height: 1.5; vertical-align: top;\"\u003eRated Short-Circuit Capacity (Icc)\u003c\/td\u003e\n    \u003ctd style=\"padding: 8px 10px; color: #555; line-height: 1.5; vertical-align: top;\"\u003e50 kA\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n    \u003ctd style=\"padding: 8px 10px; background-color: #f9f9f9; font-weight: bold; width: 35%; color: #333; line-height: 1.5; vertical-align: top;\"\u003eDegree of Protection\u003c\/td\u003e\n    \u003ctd style=\"padding: 8px 10px; color: #555; line-height: 1.5; vertical-align: top;\"\u003eIP20\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n    \u003ctd style=\"padding: 8px 10px; background-color: #f9f9f9; font-weight: bold; width: 35%; color: #333; line-height: 1.5; vertical-align: top;\"\u003eApplicable Standards\u003c\/td\u003e\n    \u003ctd style=\"padding: 8px 10px; color: #555; line-height: 1.5; vertical-align: top;\"\u003eIEC 60947-3, GB\/T 14048.3, UL 4248-1\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n    \u003ctd style=\"padding: 8px 10px; background-color: #f9f9f9; font-weight: bold; width: 35%; color: #333; line-height: 1.5; vertical-align: top;\"\u003eTerminal Wire Range\u003c\/td\u003e\n    \u003ctd style=\"padding: 8px 10px; color: #555; line-height: 1.5; vertical-align: top;\"\u003e2.0 to 16 mm² (75°C Cu Wire Only)\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n    \u003ctd style=\"padding: 8px 10px; background-color: #f9f9f9; font-weight: bold; width: 35%; color: #333; line-height: 1.5; vertical-align: top;\"\u003eTightening Torque\u003c\/td\u003e\n    \u003ctd style=\"padding: 8px 10px; color: #555; line-height: 1.5; vertical-align: top;\"\u003e2.5 to 3.5 N·m\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr style=\"border-bottom: 1px solid #e0e0e0;\"\u003e\n    \u003ctd style=\"padding: 8px 10px; background-color: #f9f9f9; font-weight: bold; width: 35%; color: #333; line-height: 1.5; vertical-align: top;\"\u003eFlammability Rating\u003c\/td\u003e\n    \u003ctd style=\"padding: 8px 10px; color: #555; line-height: 1.5; vertical-align: top;\"\u003eUL94-V0\u003c\/td\u003e\n  \u003c\/tr\u003e\n\u003c\/table\u003e","brand":"Sinofuse","offers":[{"title":"1 pcs","offer_id":53430140698903,"sku":null,"price":60.0,"currency_code":"USD","in_stock":true},{"title":"3 pcs","offer_id":53430140731671,"sku":null,"price":150.0,"currency_code":"USD","in_stock":true},{"title":"6 pcs","offer_id":53430140764439,"sku":null,"price":280.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0837\/9210\/1655\/files\/Snipaste_2026-05-25_20-14-23.png?v=1779711334","url":"https:\/\/www.apexonsupply.com\/products\/sinofuse-tsa1485-k21500vdc-32a-14x85m-fuse-holder","provider":"Apexon Solutions LLC","version":"1.0","type":"link"}