Ferraz Shawmut 27x60 URGD Semiconductor Fuses (600V-690V)
Share
Sourcing direct replacement protection devices for aging industrial drives and rectifiers can jeopardize facility uptime if original components are categorized as discontinued globally. However, we consistently stock and supply genuine Ferraz Shawmut 27x60 URGD Protistor Fuses—ensuring the uninterrupted operation of heritage system architectures without costly equipment retrofits.
Product Overview
The Ferraz Shawmut (now Mersen) URGD ferrule fuse series (27x60 mm) boasts an extremely high breaking capacity, engineered specifically to effectively shield ultra-sensitive power semiconductors. Rigorously vetted to stringent VDE and IEC 60269.4 standards, these aR-class limiters instantly isolate short-circuit faults while confining heavy system overload and minimizing total let-through thermal current (I²t).
Typical Applications
- High-speed short-circuit protection for thyristors, discrete diodes, and triac components.
- Safeguarding of complex high-power rectification frames and AC/DC converter circuits.
- Direct maintenance replacements inside OEM inverters, motor soft-starters, and VFDs.
- Protection of solid-state relays integrated into industrial heat controls and UPS systems.
Key Features & Benefits
- Tested Breaking Capacity: Performs reliably up to 200 kA at rated voltage parameters.
- Integrated Trip Monitoring: Equipped with an active trip-indicator to streamline visual fault tracking inside cabinets.
- Versatile Electrical Spectrum: Covers robust industrial load requirements from 63 A through 250 A.
- Standardized Protection Profile: Complies precisely with safety class definitions set by VDE 636-23 and strict IEC international regulations.
Available Legacy Catalog Guide
Type URGD — 600 V to 690 V AC (With Trip-indicator)
27x60 mm Ferrule format • 63 A to 250 A • Tested Breaking Capacity: 200 kA
| Catalog Number | Voltage | Current | Designation | Action |
|---|---|---|---|---|
| FR27UD69V63T Ref: A076820 | 690 V | 63 A | 6.921 CP URGD 27x60/ 63 | REQUEST QUOTE |
| FR27UD69V80T Ref: B076821 | 690 V | 80 A | 6.921 CP URGD 27x60/ 80 | REQUEST QUOTE |
| FR27UD69V100T Ref: C076822 | 690 V | 100 A | 6.921 CP URGD 27x60/100 | REQUEST QUOTE |
| FR27UD69V125T Ref: D076823 | 690 V | 125 A | 6.921 CP URGD 27x60/125 | REQUEST QUOTE |
| FR27UD69V160T Ref: E076824 | 690 V | 160 A | 6.921 CP URGD 27x60/160 | REQUEST QUOTE |
| FR27UD69V200T Ref: F076825 | 690 V | 200 A | 6.921 CP URGD 27x60/200 | REQUEST QUOTE |
| FR27UD60V250T Ref: W076264 | 600 V | 250 A | 621 CP URGD 27x60/250 | REQUEST QUOTE |
Replacing discontinued solid-state protection does not have to result in full-panel retrofits. Reach out with your desired catalog number, and our technical sourcing team will rapidly provide pricing and current inventory availability globally.
REQUEST A QUOTE