Skip to product information
1 of 1

Ferraz Shawmut Protistor FR10GB69V Series 10x38mm Semiconductor Fuses 690VAC

Regular price $22.00 USD
Regular price Sale price $22.00 USD
Sale Sold out
Shipping calculated at checkout.
Quantity
Model

Secure checkout via Credit Cards, PayPal & Bank Wire (T/T)

Visa Mastercard PayPal Apple Pay Google Pay American Express

The Ferraz Shawmut Protistor FR10GB69V series comprises 10x38 mm ferrule-type semiconductor (AC) fuses rated at 690 VAC. The manufacturer catalog identifies 17 selectable part numbers with rated currents from 1 A to 32 A. The range is primarily designated gRB; the 1 A model is specifically designated gRC, while the 32 A model is marked as a non-approval rating.

Technical Specifications

Manufacturer Ferraz Shawmut
Product Family Protistor FR10GB69V
Fuse Type Semiconductor (AC) ferrule fuse
Rated Voltage 690 VAC
Listed Rated Currents 1–30 A discrete options, plus 32 A non-approval rating
Nominal Size 10x38 mm
Overall Length 38 ± 0.6 mm
Body Diameter 10.3 ± 0.1 mm
Published Breaking Capacity 160 kA at 690 VAC (IEC), as shown in the manufacturer table; the 32 A rating is separately identified as non-approved
Trip Indicator Without trip indicator
Maximum Unit Weight 10 g
Manufacturer Packaging 10 pieces per package

Model Selection

Select the required fuse using its rated current and exact manufacturer Catalog Number. The matching Ref. Number and alternative manufacturer designation are provided for procurement identification. Only the combinations explicitly listed below are included.

Current Catalog Number Ref. Number Manufacturer Designation
1 A FR10GB69V1 Z330279 6,9 gRC 10-01 - A070 gRC 01 T13
1.25 A FR10GB69V1.25 X330001 6,9 gRB 10-1,25 - A070 gRB 1.25 T13
1.5 A FR10GB69V1.5 Y330002 6,9 gRB 10-1,5 - A070 gRB 1.5 T13
2 A FR10GB69V2 Z330003 6,9 gRB 10-02 - A070 gRB 02 T13
2.5 A FR10GB69V2.5 A330004 6,9 gRB 10-2,5 - A070 gRB 2.5 T13
3 A FR10GB69V3 B330005 6,9 gRB 10-03 - A070 gRB 03 T13
4 A FR10GB69V4 C330006 6,9 gRB 10-04 - A070 gRB 04 T13
5 A FR10GB69V5 D330007 6,9 gRB 10-05 - A070 gRB 05 T13
6 A FR10GB69V6 E330008 6,9 gRB 10-06 - A070 gRB 06 T13
8 A FR10GB69V8 F330009 6,9 gRB 10-08 - A070 gRB 08 T13
10 A FR10GB69V10 G330010 6,9 gRB 10-10 - A070 gRB 10 T13
12.5 A FR10GB69V12.5 H330011 6,9 gRB 10-12,5 - A070 gRB 12.5 T13
16 A FR10GB69V16 J330012 6,9 gRB 10-16 - A070 gRB 16 T13
20 A FR10GB69V20 K330013 6,9 gRB 10-20 - A070 gRB 20 T13
25 A FR10GB69V25 L330014 6,9 gRB 10-25 - A070 gRB 25 T13
30 A FR10GB69V30 M330015 6,9 gRB 10-30 - A070 gRB 30T13
32 A* FR10GB69V32 Y330278 6,9 gRB 10-32 - A070 gRB 32T13

*Important: The manufacturer explicitly identifies the 32 A model FR10GB69V32 as a "Non approval rating." The 1 A model FR10GB69V1 carries a gRC designation in the original reference table. These designations should be preserved when matching original equipment requirements.

Selection and Installation Notes

The manufacturer provides pre-arcing I²t data at 1 ms, total operating I²t data, dissipated power at rated current and 0.8 times rated current, time-current curves, cut-off characteristics and arc-voltage curves. These characteristics vary with the selected fuse rating and should be checked against the relevant manufacturer curves.

The published peak arc-voltage values are 2500 V for ratings from 1 A to 6 A and 1450 V for ratings from 8 A to 30 A. The original table groups the 30 A and 32 A entries for certain electrical measurements, without separate values for the 32 A model.

I²t test-condition note: The original datasheet labels the total operating I²t column at 660 VAC, while its explanatory text refers to 690 VAC. Confirm the applicable test condition before using those values for protection-coordination calculations.

The manufacturer also publishes DC working-voltage possibility curves based on the fault-path L/R time constant. These curves do not establish a single unconditional DC voltage rating. Confirm the actual DC operating conditions before selecting a fuse for DC service.

The 10x38 mm dimensional format alone does not establish electrical interchangeability. Verify the exact catalog number, current rating, fuse characteristic, interrupting requirements and applicable protection curves before replacing an existing fuse.

Applications

This product family is categorized by the manufacturer as semiconductor (AC) fuses for semiconductor circuit protection. The appropriate rating must be selected according to the protected circuit and its electrical protection requirements.

Technical Data Reference

Source: Ferraz Shawmut, "Semiconductor (AC) Fuses – Other Protistor Fuses – Ferrule Fuses – 10x38 gRB – 690VAC," document references SCAC166, SCAC167, SCAC168 and SCAC169, marked 12/04. The separately documented 10x38 URB/URD/URL 500–600 VAC range is not included in this series listing.

B2B Sourcing Support

Apexon Supply provides B2B sourcing and procurement support for the Ferraz Shawmut FR10GB69V catalog family. Buyers can use the exact Catalog Number and Ref. Number to prepare inquiries, identify required ratings and request sourcing assistance. Alternative or replacement sourcing requires separate technical verification.

For a quotation, please send your exact FR10GB69V model number, required quantity and delivery destination, together with any applicable technical requirements, to [email protected].

FR10GB69V Technical Guide

For complete model references, electrical characteristics, I²t data, dimensions, and fuse selection considerations, visit:

Ferraz Shawmut FR10GB69V 690VAC Semiconductor Fuse Technical Guide

View full details